Pregled bibliografske jedinice broj: 1113467
Unsuccessful intubation of a patient with craniotubular hyperostosis
Unsuccessful intubation of a patient with craniotubular hyperostosis // Trends in Anaesthesia and Critical Care, 30 (2020), e68-e68 doi:10.1016/j.tacc.2019.12.170 (međunarodna recenzija, kratko priopcenje, znanstveni)
CROSBI ID: 1113467 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Unsuccessful intubation of a patient with craniotubular hyperostosis
Autori
Nikolić, Mario ; Dedić, David ; Milić, Morena
Izvornik
Trends in Anaesthesia and Critical Care (2210-8440) 30
(2020);
E68-e68
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kratko priopcenje, znanstveni
Ključne riječi
unsuccessful intubation ; craniotubular hyperostosis
Sažetak
In everyday practice we come across patients with a certain anatomical characteristic which can indicate a risk of a difficult intubation. Craniotubular hyperostosis is a group of rare diseases which have in common craniofacial hyperostosis and sclerosis and tubular bones modeling defects. These changes, especially in advanced stages, can be the reason of a difficult airway.