The impact of building zone elements on airtightness
The impact of building zone elements on airtightness // Proceedings of the 2nd International Conference CoMS 2020/21 - Volume 1 / Šajna, Aljoša ; Legat, Andraž ; Jordan, Sabina ; Horvat, Petra ; Kemperle, Ema ; Dolenec, Sabina ; Ljubešek, Metka ; Michelizza, Matej (ur.).
Ljubljana: Slovenian National Building and Civil Engineering Institute (ZAG), 2021. str. 106-114 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1111416 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The impact of building zone elements on
airtightness
Autori
Gumbarević, Sanjin ; Milovanović, Bojan ; Gaši, Mergim ; Bagarić, Marina
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 2nd International Conference CoMS 2020/21 - Volume 1
/ Šajna, Aljoša ; Legat, Andraž ; Jordan, Sabina ; Horvat, Petra ; Kemperle, Ema ; Dolenec, Sabina ; Ljubešek, Metka ; Michelizza, Matej - Ljubljana : Slovenian National Building and Civil Engineering Institute (ZAG), 2021, 106-114
ISBN
978-961-94071-8-9
Skup
Construction Materials for a Sustainable Future (CoMS_2020/2021)
Mjesto i datum
Bled, Slovenija; online, 20.04.2021. - 21.04.2021
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Airtightness, Fan Pressuri sation Testing, Statistical Analysis, Nearly Zero -Energy Buildings, Blower Door
Sažetak
To achieve the goals set by the European Union (EU) in terms of energy savings and decrease of the greenhouse gas emissions, the member states of the EU obliged that they would increase the number of the Nearly Zero Energy Buildings (NZEB). That increase has to be accomplished not only by building new NZEBs but also by deep energy renovations of old ones. One of the criteria to fulfil NZEB demands is to ensure the airtightness of the building, which is usually tested by an air pressurisation test. As there will be a great number of buildings which must undergo the testing in the near future, it is important to find a way to speed up the testing for the multizone buildings. This paper presents research based on the results of building zone airtightness estimations based on a fan pressurisation test by the so-called Blower Door system. It is a part of research whose goal is to develop a predictive model of the air-change-rate for a multizone building based on randomly tested zones. The paper describes a connection between the airtightness of tested building zones and elements which make up these zones. This research is crucial as a starting point for the development of the predictive model in order to define the parameters that affect these measurements. Statistical analysis was performed not only for the analysed results but also for an exploration of the connection between the zone elements and the zone’s airtightness as well. The paper presents a hypothesis based on the abovementioned research and proposes further research for the future development of the model.