Pregled bibliografske jedinice broj: 1110145
Retention of eugenol in pectin model systems
Retention of eugenol in pectin model systems // Abstract booklet: Food Physics 2021
London : Delhi, 2021. str. 16-16 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1110145 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Retention of eugenol in pectin model systems
Autori
Ćorković, Ina ; Lukić, Josip ; Pichler, ANita ; Šimunović, Josip ; Kopjar Mirela
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Abstract booklet: Food Physics 2021
/ - London : Delhi, 2021, 16-16
Skup
Food Physics 2021
Mjesto i datum
London, Ujedinjeno Kraljevstvo, 02.02.2021. - 03.02.2021
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
eugenol ; pectin ; storage
Sažetak
Eugenol is volatile of specific flavour note, which contributes to overall flavour of many fruits and herbs. The aim of this study was investigation of behaviour of eugenol in model systems based on two different types of pectin, low-methoxy pectin (LMP) and high-methoxy pectin (HMP). For each pectin two model systems were prepared, one with 1% of pectin and other one with 2% of pectin. Model systems were stored for 30 days at room temperature to evaluate stability of eugenol in prepared systems. Amount of eugenol in model systems was evaluated by GC-MS. Also, antioxidant activity of prepared model systems was determined by application of DPPH, FRAP and CUPRAC methods. After preparation, HMP-1% had higher amount of eugenol (48.03 µg/mL) then HMP- 2% (40.23 µg/mL). Compering systems prepared with LMP there were no difference between systems with 1% and 2% of pectin (45 µg/mL). After storage, loss of eugenol was observed. Different trend for model systems with HMP was observed. HMP-1% had lower amount of eugenol (22.48 µg/mL) then HMP-2% (26.79 µg/mL). Model systems with LMP had higher amount of eugenol, than HMP systems, 31.47 µg/mL and 29.41 µg/mL for 1% and 2% of pectin, respectively. Consequently, LMP systems had higher retention of eugenol after storage, 69% and 66% for 1% and 2% of pectin, respectively. Retention of eugenol in HMP systems was 46% and 66% for 1% and 2% of pectin, respectively. Antioxidant activity of model systems was higher when 2% of pectin was used for preparation regardless of pectin type and evaluation method, while after storage there were no difference between systems with 1% and 2%. These results showed importance of pectin type and amount on retention of eugenol after preparation as well as after storage.
Izvorni jezik
Engleski
Znanstvena područja
Prehrambena tehnologija
POVEZANOST RADA
Projekti:
HRZZ-IP-2019-04-5749 - Formuliranje, priprema i testiranje biopolimernih gelova kao nositelja bioaktivnih i hlapljivih komponenata u inovativnim funkcionalnim proizvodima (bioACTIVEgels) (Kopjar, Mirela, HRZZ ) ( CroRIS)
Ustanove:
Prehrambeno-tehnološki fakultet, Osijek