Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1109372

The Fermilab Muon g-2 experiment: laser calibration system


Karuza, M.; Anastasi, A.; Basti, A.; Bedeschi, F.; Bartolini, M.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Sciascio, G. Di et al.
The Fermilab Muon g-2 experiment: laser calibration system // Journal of Instrumentation, 12 (2017), 08; C08019-C08019 doi:10.1088/1748-0221/12/08/c08019 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1109372 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The Fermilab Muon g-2 experiment: laser calibration system

Autori
Karuza, M. ; Anastasi, A. ; Basti, A. ; Bedeschi, F. ; Bartolini, M. ; Cantatore, G. ; Cauz, D. ; Corradi, G. ; Dabagov, S. ; Sciascio, G. Di ; Stefano, R. Di ; Driutti, A. ; Escalante, O. ; Ferrari, C. ; Fioretti, A. ; Gabbanini, C. ; Gioiosa, A. ; Hampai, D. ; Iacovacci, M. ; Liedl, A. ; Lusiani, A. ; Marignetti, F. ; Mastroianni, S. ; Moricciani, D. ; Nath, A. ; Pauletta, G. ; Piacentino, G.M. ; Raha, N. ; Santi, L. ; Venanzoni, G.

Izvornik
Journal of Instrumentation (1748-0221) 12 (2017), 08; C08019-C08019

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Detector alignment and calibration methods (lasers, sources, particle-beams) ; Cherenkov detectors ; Optics ; Lasers

Sažetak
The anomalous muon dipole magnetic moment can be measured (and calculated) with great precision thus providing insight on the Standard Model and new physics. Currently an experiment is under construction at Fermilab (U.S.A.) which is expected to measure the anomalous muon dipole magnetic moment with unprecedented precision. One of the improvements with respect to the previous experiments is expected to come from the laser calibration system which has been designed and constructed by the Italian part of the collaboration (INFN). Furthermore, an emphasis of this paper will be on the calibration system that is in the final stages of construction as well as the experiment which is expected to start data taking this year.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Sveučilište u Rijeci - Odjel za fiziku

Profili:

Avatar Url Marin Karuza (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Karuza, M.; Anastasi, A.; Basti, A.; Bedeschi, F.; Bartolini, M.; Cantatore, G.; Cauz, D.; Corradi, G.; Dabagov, S.; Sciascio, G. Di et al.
The Fermilab Muon g-2 experiment: laser calibration system // Journal of Instrumentation, 12 (2017), 08; C08019-C08019 doi:10.1088/1748-0221/12/08/c08019 (međunarodna recenzija, članak, znanstveni)
Karuza, M., Anastasi, A., Basti, A., Bedeschi, F., Bartolini, M., Cantatore, G., Cauz, D., Corradi, G., Dabagov, S. & Sciascio, G. (2017) The Fermilab Muon g-2 experiment: laser calibration system. Journal of Instrumentation, 12 (08), C08019-C08019 doi:10.1088/1748-0221/12/08/c08019.
@article{article, author = {Karuza, M. and Anastasi, A. and Basti, A. and Bedeschi, F. and Bartolini, M. and Cantatore, G. and Cauz, D. and Corradi, G. and Dabagov, S. and Sciascio, G. Di and Stefano, R. Di and Driutti, A. and Escalante, O. and Ferrari, C. and Fioretti, A. and Gabbanini, C. and Gioiosa, A. and Hampai, D. and Iacovacci, M. and Liedl, A. and Lusiani, A. and Marignetti, F. and Mastroianni, S. and Moricciani, D. and Nath, A. and Pauletta, G. and Piacentino, G.M. and Raha, N. and Santi, L. and Venanzoni, G.}, year = {2017}, pages = {C08019-C08019}, DOI = {10.1088/1748-0221/12/08/c08019}, keywords = {Detector alignment and calibration methods (lasers, sources, particle-beams), Cherenkov detectors, Optics, Lasers}, journal = {Journal of Instrumentation}, doi = {10.1088/1748-0221/12/08/c08019}, volume = {12}, number = {08}, issn = {1748-0221}, title = {The Fermilab Muon g-2 experiment: laser calibration system}, keyword = {Detector alignment and calibration methods (lasers, sources, particle-beams), Cherenkov detectors, Optics, Lasers} }
@article{article, author = {Karuza, M. and Anastasi, A. and Basti, A. and Bedeschi, F. and Bartolini, M. and Cantatore, G. and Cauz, D. and Corradi, G. and Dabagov, S. and Sciascio, G. Di and Stefano, R. Di and Driutti, A. and Escalante, O. and Ferrari, C. and Fioretti, A. and Gabbanini, C. and Gioiosa, A. and Hampai, D. and Iacovacci, M. and Liedl, A. and Lusiani, A. and Marignetti, F. and Mastroianni, S. and Moricciani, D. and Nath, A. and Pauletta, G. and Piacentino, G.M. and Raha, N. and Santi, L. and Venanzoni, G.}, year = {2017}, pages = {C08019-C08019}, DOI = {10.1088/1748-0221/12/08/c08019}, keywords = {Detector alignment and calibration methods (lasers, sources, particle-beams), Cherenkov detectors, Optics, Lasers}, journal = {Journal of Instrumentation}, doi = {10.1088/1748-0221/12/08/c08019}, volume = {12}, number = {08}, issn = {1748-0221}, title = {The Fermilab Muon g-2 experiment: laser calibration system}, keyword = {Detector alignment and calibration methods (lasers, sources, particle-beams), Cherenkov detectors, Optics, Lasers} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font