Pregled bibliografske jedinice broj: 1101196
Application of Deep Eutectic Solvents for the Extraction of Carnosic Acid and Carnosol from Sage (Salvia officinalis L.) with Response Surface Methodology Optimization
Application of Deep Eutectic Solvents for the Extraction of Carnosic Acid and Carnosol from Sage (Salvia officinalis L.) with Response Surface Methodology Optimization // Plants, 10 (2021), 80, 20 doi:10.3390/plants10010080 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1101196 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Application of Deep Eutectic Solvents for the Extraction of
Carnosic Acid and Carnosol from Sage (Salvia officinalis L.)
with Response Surface Methodology Optimization
Autori
Jakovljević, Martina ; Jokić, Stela ; Molnar, Maja ; Jerković, Igor
Izvornik
Plants (2223-7747) 10
(2021);
80, 20
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
sage ; optimization ; stirring and heating extraction ; ultrasound-assisted extraction ; mechanochemical extraction
Sažetak
Salvia officinalis L. is a good source of antioxidant compounds such as phenolic diterpenes carnosic acid and carnosol. From 17 deep eutectic solvents (DESs) used, choline chloride: lactic acid (1:2 molar ratio) was found to be the most suitable for the extraction of targeted compounds. The influence of H2O content, extraction time, and temperature (for stirring and heating and for ultrasound assisted extraction (UAE)), H2O content, extraction time, and vibration speed for mechanochemical extraction on the content of targeted compounds were investigated. Carnosic acid content obtained by the extraction assisted by stirring and heating was from 2.55 - 0.04 to 14.43 - 0.28 g/mg, for UAE it was from 1.62 - 0.29 to 14.00 - 0.02 g/mg, and for mechanochemical extraction the yield was from 1.80 - 0.02 to 8.26 - 0.45 g/mg. Determined carnosol content was in the range 0.81 - 0.01 to 4.83 - 0.09 g/mg for the extraction with stirring and for UAE it was from 0.56 - 0.02 to 4.18 - 0.05 g/mg, and for mechanochemical extraction the yield was from 0.57 - 0.11 to 2.01 - 0.16 g/mg. Optimal extraction conditions determined by response surface methodology (RSM) were in accordance with experimentally demonstrated values. In comparison with previously published or own results using conventional solvents or supercritical CO2, used DES provided more efficient extraction of both targeted compounds.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Farmacija, Prehrambena tehnologija
POVEZANOST RADA
Ustanove:
Kemijsko-tehnološki fakultet, Split,
Prehrambeno-tehnološki fakultet, Osijek
Profili:
Martina Jakovljević Kovač
(autor)
Stela Jokić
(autor)
Igor Jerković
(autor)
Maja Molnar
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus