Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1098464

General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine


Rimac, Vladimira; Jokić, Anja; Podolar, Sonja; Vlašić Tanasković, Jelena; Honović, Lorena; Leniček Krleža, Jasna
General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine // Biochemia medica, 30 (2020), 2; 1-8 doi:10.11613/BM.2020.020702 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1098464 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine

Autori
Rimac, Vladimira ; Jokić, Anja ; Podolar, Sonja ; Vlašić Tanasković, Jelena ; Honović, Lorena ; Leniček Krleža, Jasna

Izvornik
Biochemia medica (1330-0962) 30 (2020), 2; 1-8

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
postanalytical phase ; autovalidation ; clinical laboratory ; questionnaire

Sažetak
Introduction: Autovalidation (AV) is an algorithm based on predefined rules designed, among others, to automate and standardize the postanalytical phase of laboratory work. The aim of this study was to examine the overall opinion of Croatian medical biochemistry laboratories regarding various aspects of AV. Material and methods: This retrospective study is an analysis of the responses of a survey about AV comprised of 18 questions, as part of Module 10 (“Postanalytical phase of laboratory testing”) of national External Quality Assessment program, administered by the Croatian Centre for Quality Assessment in Laboratory Medicine. Results were reported as percentages of total number of participants in survey or as proportions of observed data if the overall number of data was <100. Results: 121 laboratories responded to the survey, of which 76% do not use AV, while 11% of laboratories use AV in routine laboratory work. 16/29 laboratories implemented semi-automated AV for general biochemistry (7/29), haematology (5/29), and coagulation (4/29) tests. Analytical measurement ranges, critical values, flags from analysers, interference indices and delta check were the most commonly used rules in the algorithm. 12/29 laboratories performed validation of AV with less than 500 samples (8/29). 7/13 laboratories report the percentage of AV being 20- 50%, while 10/13 answered that introduction of AV significantly reduced turnaround time (TAT) (for 20 - 25%), especially for biochemistry tests. Conclusions: Despite of its numerous benefits (i.e. shorter TAT, less manual validation, standardization of the postanalytical phase), only a small number of Croatian laboratories use AV.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinika za infektivne bolesti "Dr Fran Mihaljević",
Opća bolnica Pula,
Klinički bolnički centar Zagreb,
Klinika za dječje bolesti

Poveznice na cjeloviti tekst rada:

doi www.biochemia-medica.com

Citiraj ovu publikaciju:

Rimac, Vladimira; Jokić, Anja; Podolar, Sonja; Vlašić Tanasković, Jelena; Honović, Lorena; Leniček Krleža, Jasna
General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine // Biochemia medica, 30 (2020), 2; 1-8 doi:10.11613/BM.2020.020702 (međunarodna recenzija, članak, znanstveni)
Rimac, V., Jokić, A., Podolar, S., Vlašić Tanasković, J., Honović, L. & Leniček Krleža, J. (2020) General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochemia medica, 30 (2), 1-8 doi:10.11613/BM.2020.020702.
@article{article, author = {Rimac, Vladimira and Joki\'{c}, Anja and Podolar, Sonja and Vla\v{s}i\'{c} Tanaskovi\'{c}, Jelena and Honovi\'{c}, Lorena and Leni\v{c}ek Krle\v{z}a, Jasna}, year = {2020}, pages = {1-8}, DOI = {10.11613/BM.2020.020702}, keywords = {postanalytical phase, autovalidation, clinical laboratory, questionnaire}, journal = {Biochemia medica}, doi = {10.11613/BM.2020.020702}, volume = {30}, number = {2}, issn = {1330-0962}, title = {General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine}, keyword = {postanalytical phase, autovalidation, clinical laboratory, questionnaire} }
@article{article, author = {Rimac, Vladimira and Joki\'{c}, Anja and Podolar, Sonja and Vla\v{s}i\'{c} Tanaskovi\'{c}, Jelena and Honovi\'{c}, Lorena and Leni\v{c}ek Krle\v{z}a, Jasna}, year = {2020}, pages = {1-8}, DOI = {10.11613/BM.2020.020702}, keywords = {postanalytical phase, autovalidation, clinical laboratory, questionnaire}, journal = {Biochemia medica}, doi = {10.11613/BM.2020.020702}, volume = {30}, number = {2}, issn = {1330-0962}, title = {General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine}, keyword = {postanalytical phase, autovalidation, clinical laboratory, questionnaire} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font