Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1094676

Co-heating test as a tool for reduction of energy performance gap in buildings


Krstić, Hrvoje; Domazetović, Mihaela
Co-heating test as a tool for reduction of energy performance gap in buildings // International Journal of Energy Production and Management, 5 (2020), 4; 328-341 doi:10.2495/EQ-V5-N4-328-341 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1094676 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Co-heating test as a tool for reduction of energy performance gap in buildings

Autori
Krstić, Hrvoje ; Domazetović, Mihaela

Izvornik
International Journal of Energy Production and Management (2056-3272) 5 (2020), 4; 328-341

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
actual energy needs ; Co-heating test ; design energy needs ; energy performance gap ; heat loss coefficient ; temperature-based method (TBM) ; ventilation and transmission heat loss

Sažetak
This paper presents part of the results of a large- scale, long-term experimental research conducted at the Faculty of Civil Engineering and Architecture Osijek. Among other research goals, this research aims at further development and improvement of a relatively new method used for the measurement of ther- mal transmittance of walls (U-value) in literature, often called temperature-based method (TBM). This research also partially overlaps with other researches carried out at the Faculty of Economics in Osijek, where the main research goals were development of machine learning and neural network models for predicting energy consumption in buildings, which will reduce the energy performance gap between design and actual energy needs. Building thermal performance as a whole can be quantified by the heat loss coefficient (HLC) or the total heat loss (THL). Experimental research presented in this paper was conducted by using a built test chamber in a laboratory, and the research lasted for 40 days. This is an innovative element of this research, since the test chamber is built inside a laboratory where external weather conditions are simulated by omitting the negative influence of wind, precipitation, and solar radiation on the experimental results. The actual heating energy consumption by the test chamber was recorded daily for 40 days during the winter season, together with internal and external temperatures, relative humidity (RH), U-values of walls, and wind speed. Chamber airtightness was measured at the beginning of the experiment. These measurements made it possible to perform the Co- heating test. This test is used to calculate the total heat loss of a building, both fabric and ventilation loss. Parallel with the Co-heating test, the design heating energy need of the test chamber was determined by calculating the heat loss coefficient and the total heat loss. Actual and design values of heat loss coefficient and total heat loss were used to characterize the energy performance gap. Energy performance gap in this study was found to be between −40% and 13%. Research results indicate the variables affecting the actual and design values of heat losses significantly. Presented results provide guidance for more accurate determination of actual energy consumption in buildings, and therefore help in the reduction of the energy performance gap.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo

Napomena
ACKNOWLEDGMENT
This work has been fully supported by Croatian
Science Foundation under Grant No. IP-201606-8350
‘Methodological Framework for Efficient Energy
Management by Intelligent Data Analytics’
(MERIDA).



POVEZANOST RADA


Projekti:
IP-2016-06-8350 - Metodološki okvir za učinkovito upravljanje energijom s pomoću inteligentne podatkovne analitike (MERIDA) (Zekić-Sušac, Marijana, HRZZ - 2016-06) ( CroRIS)

Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Mihaela Domazetović (autor)

Avatar Url Hrvoje Krstić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.witpress.com

Citiraj ovu publikaciju:

Krstić, Hrvoje; Domazetović, Mihaela
Co-heating test as a tool for reduction of energy performance gap in buildings // International Journal of Energy Production and Management, 5 (2020), 4; 328-341 doi:10.2495/EQ-V5-N4-328-341 (međunarodna recenzija, članak, znanstveni)
Krstić, H. & Domazetović, M. (2020) Co-heating test as a tool for reduction of energy performance gap in buildings. International Journal of Energy Production and Management, 5 (4), 328-341 doi:10.2495/EQ-V5-N4-328-341.
@article{article, author = {Krsti\'{c}, Hrvoje and Domazetovi\'{c}, Mihaela}, year = {2020}, pages = {328-341}, DOI = {10.2495/EQ-V5-N4-328-341}, keywords = {actual energy needs, Co-heating test, design energy needs, energy performance gap, heat loss coefficient, temperature-based method (TBM), ventilation and transmission heat loss}, journal = {International Journal of Energy Production and Management}, doi = {10.2495/EQ-V5-N4-328-341}, volume = {5}, number = {4}, issn = {2056-3272}, title = {Co-heating test as a tool for reduction of energy performance gap in buildings}, keyword = {actual energy needs, Co-heating test, design energy needs, energy performance gap, heat loss coefficient, temperature-based method (TBM), ventilation and transmission heat loss} }
@article{article, author = {Krsti\'{c}, Hrvoje and Domazetovi\'{c}, Mihaela}, year = {2020}, pages = {328-341}, DOI = {10.2495/EQ-V5-N4-328-341}, keywords = {actual energy needs, Co-heating test, design energy needs, energy performance gap, heat loss coefficient, temperature-based method (TBM), ventilation and transmission heat loss}, journal = {International Journal of Energy Production and Management}, doi = {10.2495/EQ-V5-N4-328-341}, volume = {5}, number = {4}, issn = {2056-3272}, title = {Co-heating test as a tool for reduction of energy performance gap in buildings}, keyword = {actual energy needs, Co-heating test, design energy needs, energy performance gap, heat loss coefficient, temperature-based method (TBM), ventilation and transmission heat loss} }

Časopis indeksira:


  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font