Pregled bibliografske jedinice broj: 1093298
Control methods for Line-interactive Uninterruptible Power Supply with Shunt Active Power Filter Function
Control methods for Line-interactive Uninterruptible Power Supply with Shunt Active Power Filter Function // Proceedings of the 2020 IEEE 11th International Symposium on Power Electronics for Distributed Generation Systems (PEDG) / Matuško, Jadranko ; Jakopović, Željko (ur.).
Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2020. str. 602-609 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1093298 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Control methods for Line-interactive
Uninterruptible Power Supply with Shunt Active
Power Filter Function
Autori
Perić, Ante ; Ileš, Šandor ; Ban, Željko ; Šunde, Viktor
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 2020 IEEE 11th International Symposium on Power Electronics for Distributed Generation Systems (PEDG)
/ Matuško, Jadranko ; Jakopović, Željko - Zagreb : Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2020, 602-609
ISBN
978-1-7281-6989-7
Skup
IEEE 11th International Symposium on Power Electronics for Distributed Generation Systems (PEDG)
Mjesto i datum
Online, 28.09.2020. - 01.10.2020
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
non-linear loads, unity power factor, active power filter, uninterruptible power supply, model predictive control, modified sine PWM method
Sažetak
With the increasing number of non-linear loads in industry and households, power quality is given more importance. Power supply continuity and unity power factor are the requirements on the grid and load, respectively. Both of these requirements are satisfied by the application of a hybrid UPS/APF system that can operate as an uninterruptible power supply (UPS) and as an active power filter (APF). Such a hybrid UPS/APF system is a modification of the Line- interactive single conversion UPS system. When working as an APF, i.e. achieving a unity power factor, the hybrid UPS/APF injects such a current into the point of common coupling (PCC) that the source current becomes a sine wave synchronous with the source voltage. When working as a UPS, it supplies non-linear loads with power as when they were connected to the sine AC grid. The hybrid UPS/APF system consists of two converter circuits, i.e. the inverter/rectifier and the bidirectional DC/DC converter, and hybrid energy storage composed of a supercapacitor and battery. This paper presents a simulation model in which simulation experiments tested the functionality of the converters control methods of a hybrid UPS/APF system when operating in both modes. This paper also analyzes the model predictive control (MPC) algorithm for inverter/rectifier when working as an active power filter and the modified SPWM method when working as a UPS system.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb