Pregled bibliografske jedinice broj: 1091015
COMPARISON OF VERTICAL BRIDGE ACCELERATION ACCORDING TO UK NA 1992-1 AND ANNEX B TO EN 1995-2
COMPARISON OF VERTICAL BRIDGE ACCELERATION ACCORDING TO UK NA 1992-1 AND ANNEX B TO EN 1995-2 // GNP 2020 PROCEEDINGS / Rakočević, M. ; Šćepanović, B. (ur.).
Podgorica: UNIVERSITY OF MONTENEGRO FACULTY OF CIVIL ENGINEERING, 2020. str. 775-782 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1091015 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
COMPARISON OF VERTICAL BRIDGE ACCELERATION
ACCORDING TO UK NA 1992-1 AND ANNEX B TO EN 1995-2
Autori
Drobac, Jug ; štimac Grandić, Ivana
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
GNP 2020 PROCEEDINGS
/ Rakočević, M. ; Šćepanović, B. - Podgorica : UNIVERSITY OF MONTENEGRO FACULTY OF CIVIL ENGINEERING, 2020, 775-782
ISBN
978-86-82707-32-5
Skup
7th International Conference Civil Engineering Science & Practice
Mjesto i datum
Kolašin, Crna Gora, 12.03.2020. - 14.03.2020
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
bridge vibration, acceleration, UK NA 1992-1, Annex B to EN 1995-2
Sažetak
Researchers have known of the problem of the evaluation of the dynamic response of footbridges due to pedestrian loading more than a century ago, but it has been intensively explored over the past 20 years. Footbridges made of modern lightweight materials as well as extreme slender footbridges made of traditional materials often experience excessive vibrations unpleasant for pedestrians. Although an incredibly large amount of research has emerged on the topic, the problem of vibrations is very poorly represented in European standards for structural design (Eurocodes). The requirement for verification of pedestrian comfort criteria may be found in EN 1990 and EN 1991-2. The recommended maximum acceleration of any part of the bridge deck is defined in EN 1990. Unfortunately, the dynamic load models of pedestrian loads are not given in any part of Eurocode. Only the Annex B to Eurocode EN 1995- 2:2013: Design of timber structures gives expressions to determine the vertical and horizontal acceleration of the timber bridges with simply supported beams or truss systems. Also, the UK National Annex to Eurocode EN 1991-2:2003: Actions on structures gives models of pedestrian loads, using which is possible to calculate the vertical acceleration of the bridge. In this paper, the calculations of maximum vertical acceleration on two fictional pedestrian bridges are made according to Annex B to Eurocode EN 1995- 2:2013 and UK National Annex to Eurocode EN 1991- 2:2003 (two different Annexes to European standards). The results of the calculations are presented and compared.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo
Napomena
Rad je dio projekta uniri-tehnic-18-127
POVEZANOST RADA
Projekti:
NadSve-Sveučilište u Rijeci-uniri-tehnic-18-127 - Poboljšanje proračunskih modela za ocjenu stanja građevinskih konstrukcija (Štimac Grandić, Ivana, NadSve ) ( CroRIS)
Ustanove: