Pregled bibliografske jedinice broj: 1076971
Biomechanics of fetal membranes – relation with newborn and maternal anthropometric data
Biomechanics of fetal membranes – relation with newborn and maternal anthropometric data // Periodicum biologorum, 119 (2017), 2; 119-123 doi:10.18054/pb.v119i2.4660 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1076971 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Biomechanics of fetal membranes – relation with newborn and maternal anthropometric data
Autori
Šumanovac, Antun ; Baškarić, Tomislav ; Sorić, Tomislav ; Selthofer, Robert
Izvornik
Periodicum biologorum (0031-5362) 119
(2017), 2;
119-123
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
anthropometric data ; biomechanics ; BMI ; body mass index ; fetal membranes
Sažetak
Background and purpose: Cyclic biaxial burst test is a novel approach in biomechanical testing of fetal membranes. The purpose of the study is to determine are there differences between cyclic biaxial burst test and standard burst test. Relations between newborn and maternal anthropometric data and membrane biomechanics were investigated. Materials and methods: Thirty-nine fetal membranes were tested. Each membrane was cut in half acquiring one half closer to placenta and one closer to cervix. Samples for tensile, biaxial cyclic and standard tests were taken from each. Maternal and newborn anthropometric data was examined. Results: Cyclic burst pressures were significantly higher than standard burst pressures in samples closer to placenta (83.8 ± 19.4 vs 69.3 ± 17.9 mmHg ; p<0.001) and cervix (67.9 ± 23.4 vs 58.1 ± 15.8 mmHg ; p=0.013). When compared according to type of delivery, cyclic pressures were higher than standard in c-section samples (80.6 ± 22.4 vs 59.1 ± 14.8 mmHg ; p<0.001) and vaginally delivered samples (73.5 ± 22.7 vs 65.9 ± 18.6 mmHg ; p=0.017). Positive correlation between pregnancy BMI and uniaxial test rupture force was established. Conclusions: Cyclic biaxial test is closer to physiological conditions and tests membrane viscoelastic properties better than standard test. A positive correlation between maternal pregnancy BMI and uniaxial force-to-rupture may indicate a connection between maternal nutritional status and fetal membrane strength.
Izvorni jezik
Engleski
Znanstvena područja
Interdisciplinarne biotehničke znanosti, Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Osijek
Profili:
Robert Selthofer
(autor)
Tomislav Sorić
(autor)
Tomislav Baškarić
(autor)
Antun Šumanovac
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus