Velagic, Vedran; Prepolec, Ivan; Pasara, Vedran; Pezo-Nikolic, Borka; Puljevic, Mislav; Matasic, Richard; Krpan, Miroslav; Lovric- Bencic, Martina; Puljevic, Davor; Milicic, Davor
Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure // EP Europace 22, Suppl. 1
online, 2020. str. p451-p451 doi:10.1093/europace/euaa162.019 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 1074859 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure

Autori
Velagic, Vedran ; Prepolec, Ivan ; Pasara, Vedran ; Pezo-Nikolic, Borka ; Puljevic, Mislav ; Matasic, Richard ; Krpan, Miroslav ; Lovric- Bencic, Martina ; Puljevic, Davor ; Milicic, Davor

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
EP Europace 22, Suppl. 1 / - , 2020, P451-p451

Skup
EHRA 2020.

Mjesto i datum
Online, 00.00.0000

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
atrial fibrillation pseudoaneurysm arteriovenous fistula ultrasonography cardiac ablation hemorrhage hemostatic function hematoma bandages conscious sedation femoral vein

Sažetak
As catheter ablation became the standard therapy for atrial fibrillation (AF), the number of AF procedures has risen exponentially. Therefore, workflow optimization is crucial in order to meet the rising demands for EP interventions. Recently, instead of standard groin compression we have started using the "Z stitch" for introducers’ removal. This novel method does not necessitate protamine administration and often lengthy manual compression. Purpose We aim to demonstrate utilization of "Z stitch" for groin access closure in cryoballoon (CB) ablation and its impact on EP lab workflow. Methods We have analyzed all patients having undergone CB ablation utilizing the "Z stitch" (Z group) and the last 50 consecutive CB patients who received standard groin compression (non-Z group). Procedures were performed under conscious sedation. Both femoral veins were punctured and a single introducer was placed in each vein. A single transeptal puncture was preformed guided by intracardial ultrasound and a 28 mm cryoballoon was used. A single 180 seconds freeze strategy was employed. In the past, protamine was slowly administered after ablation and at least 15 minute manual groin compression was applied until no visual bleeding could be detected. Elastic bandage was placed around both groins. Later on, the "Z stitch" was used around both introducers without the need for protamine administration, manual compression and bandage placement (Picture). The stitches were removed next morning. Results A total of 100 consecutive patients (79% male, 61.2 ± 10.6 years old) were evaluated, 50 in both groups. There was no difference in the mean procedure duration ("skin to skin") between two groups. However, a total lab time was significantly longer in non- Z group. There was no differences in complication rates, which consisted solely of phrenic nerve palsy and groin complications. There was no AV fistula or pseudoaneurysms detected in our cohort (Table). Conclusion Utilization of Z stitches for introduces’ removal seems safe and effective way to achieve hemostasis after cryoballoon ablation. It abolishes the need for protamine administration which can cause serious advert events. Manual compression is no longer required. Consequently, EP lab workflow is improved, since the total lab time utilization per patient is significantly shortened. Results non-Z group Z group p Procedure duration (min) 69.4 ± 20.4 73.4 ± 24.8 0.380 Lab time (min) 129.9 ± 35.3 109.1 ± 30.6 0.002 Complications (N) 5 (2 hematoma) 4 (2 hematoma) NS

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Velagic, Vedran; Prepolec, Ivan; Pasara, Vedran; Pezo-Nikolic, Borka; Puljevic, Mislav; Matasic, Richard; Krpan, Miroslav; Lovric- Bencic, Martina; Puljevic, Davor; Milicic, Davor
Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure // EP Europace 22, Suppl. 1
online, 2020. str. p451-p451 doi:10.1093/europace/euaa162.019 (poster, međunarodna recenzija, sažetak, stručni)
Velagic, V., Prepolec, I., Pasara, V., Pezo-Nikolic, B., Puljevic, M., Matasic, R., Krpan, M., Lovric- Bencic, M., Puljevic, D. & Milicic, D. (2020) Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure. U: EP Europace 22, Suppl. 1 doi:10.1093/europace/euaa162.019.
@article{article, author = {Velagic, Vedran and Prepolec, Ivan and Pasara, Vedran and Pezo-Nikolic, Borka and Puljevic, Mislav and Matasic, Richard and Krpan, Miroslav and Lovric- Bencic, Martina and Puljevic, Davor and Milicic, Davor}, year = {2020}, pages = {p451-p451}, DOI = {10.1093/europace/euaa162.019}, keywords = {atrial fibrillation pseudoaneurysm arteriovenous fistula ultrasonography cardiac ablation hemorrhage hemostatic function hematoma bandages conscious sedation femoral vein}, doi = {10.1093/europace/euaa162.019}, title = {Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure}, keyword = {atrial fibrillation pseudoaneurysm arteriovenous fistula ultrasonography cardiac ablation hemorrhage hemostatic function hematoma bandages conscious sedation femoral vein}, publisherplace = {online} }
@article{article, author = {Velagic, Vedran and Prepolec, Ivan and Pasara, Vedran and Pezo-Nikolic, Borka and Puljevic, Mislav and Matasic, Richard and Krpan, Miroslav and Lovric- Bencic, Martina and Puljevic, Davor and Milicic, Davor}, year = {2020}, pages = {p451-p451}, DOI = {10.1093/europace/euaa162.019}, keywords = {atrial fibrillation pseudoaneurysm arteriovenous fistula ultrasonography cardiac ablation hemorrhage hemostatic function hematoma bandages conscious sedation femoral vein}, doi = {10.1093/europace/euaa162.019}, title = {Optimizing the EP lab workflow in atrial fibrillation ablation - The use of Z stitch for groin access closure}, keyword = {atrial fibrillation pseudoaneurysm arteriovenous fistula ultrasonography cardiac ablation hemorrhage hemostatic function hematoma bandages conscious sedation femoral vein}, publisherplace = {online} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font