Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms


Velagic, Vedran; Prepolec, Ivan; Pasara, Vedran; Kardum, Domagoj; Pezo-Nikolic, Borka; Puljevic, Mislav; Matasic, Richard; Krpan, Miroslav; Lovric-Bencic, Martina; Puljevic, Davor; Milicic, Davor
Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms // EP Europace 22, Suppl. 1
online, 2020. str. p420-p420 doi:10.1093/europace/euaa162.018 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 1074858 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms

Autori
Velagic, Vedran ; Prepolec, Ivan ; Pasara, Vedran ; Kardum, Domagoj ; Pezo-Nikolic, Borka ; Puljevic, Mislav ; Matasic, Richard ; Krpan, Miroslav ; Lovric-Bencic, Martina ; Puljevic, Davor ; Milicic, Davor

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
EP Europace 22, Suppl. 1 / - , 2020, P420-p420

Skup
EHRA 2020

Mjesto i datum
Online, 00.00.0000

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
atrial fibrillation, ultrasonography, balloon dilatation atrium ventricular tachycardia, induced heart valve bioprosthesis stenosis conscious sedation pulmonary veins freezing sinus rhythm catheters medical devices ablation

Sažetak
The third-generation cryoballoon has been designed with a 40% shortened tip length compared with the former second- generation CB device. Ideally, a shorter tip could result with an improved visualization of real-time (RT) recordings in the pulmonary vein (PV) due to a more proximal positioning of the inner lumen mapping catheter. Beside the high incidence of RT recordings, for the first time, we observed dual fascicle electrograms with different isolation time for each fascicle, when using the new device. Purpose We sought to analyze the rate of visualization of RT recordings and dual fascicle electrograms in our first series of patients with the third generation cryoballoon device. Methods All consecutive patients having undergone CB ablation using the third generation technology were analyzed. Procedures were performed under conscious sedation. A single transeptal puncture was preformed guided by intracardial ultrasound and a 28 mm cryoballoon was used. A single 180 seconds freeze strategy was employed. Results A total of 80 consecutive patients (77.5% male, 60.3 ± 10.8 years) were evaluated. Real-time recordings were detected in 275 of 320 PVs (85.9%). Specifically, RT recordings could be visualized in 68 left superior PVs (85%), 69 left inferior PVs (86.2%), 73 right superior PVs (91.2%), and 65 right inferior PVs (81.2%). Furthermore, in 14 of 320 PVs (4.3%) two different fascicles electrograms were detected. A distinctive isolation time for each fascicle could be observed both in sinus rhythm and in atrial fibrillation (Picture). Most commonly, dual fascicles were observed in left superior PV (7.5%) and right inferior PV (6.3%). In the rest of the veins this phenomenon was not so frequent. In 2.5% of right superior PV and in only 1.2% of left inferior PV dual fascicles could be observed. Conclusion The rate of visualization of RT recordings is significantly high during third generation CB ablation. Real-time recordings can be visualized in 85.9% of veins with this novel cryoballoon. Furthermore, for the first time, isolation of two different fascicles during a single cryoballoon lesion could be observed. Other that more proximal mapping catheter position, there is second possible explanation for the visualization of dual fascicles with this novel balloon. Shorter tip could result with poorer cryoballoon stability and weaker contact with the atrium wall, hence non- uniform freezing and isolation of different fascicles in different times.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Velagic, Vedran; Prepolec, Ivan; Pasara, Vedran; Kardum, Domagoj; Pezo-Nikolic, Borka; Puljevic, Mislav; Matasic, Richard; Krpan, Miroslav; Lovric-Bencic, Martina; Puljevic, Davor; Milicic, Davor
Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms // EP Europace 22, Suppl. 1
online, 2020. str. p420-p420 doi:10.1093/europace/euaa162.018 (poster, međunarodna recenzija, sažetak, stručni)
Velagic, V., Prepolec, I., Pasara, V., Kardum, D., Pezo-Nikolic, B., Puljevic, M., Matasic, R., Krpan, M., Lovric-Bencic, M., Puljevic, D. & Milicic, D. (2020) Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms. U: EP Europace 22, Suppl. 1 doi:10.1093/europace/euaa162.018.
@article{article, author = {Velagic, Vedran and Prepolec, Ivan and Pasara, Vedran and Kardum, Domagoj and Pezo-Nikolic, Borka and Puljevic, Mislav and Matasic, Richard and Krpan, Miroslav and Lovric-Bencic, Martina and Puljevic, Davor and Milicic, Davor}, year = {2020}, pages = {p420-p420}, DOI = {10.1093/europace/euaa162.018}, keywords = {atrial fibrillation, ultrasonography, balloon dilatation atrium ventricular tachycardia, induced heart valve bioprosthesis stenosis conscious sedation pulmonary veins freezing sinus rhythm catheters medical devices ablation}, doi = {10.1093/europace/euaa162.018}, title = {Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms}, keyword = {atrial fibrillation, ultrasonography, balloon dilatation atrium ventricular tachycardia, induced heart valve bioprosthesis stenosis conscious sedation pulmonary veins freezing sinus rhythm catheters medical devices ablation}, publisherplace = {online} }
@article{article, author = {Velagic, Vedran and Prepolec, Ivan and Pasara, Vedran and Kardum, Domagoj and Pezo-Nikolic, Borka and Puljevic, Mislav and Matasic, Richard and Krpan, Miroslav and Lovric-Bencic, Martina and Puljevic, Davor and Milicic, Davor}, year = {2020}, pages = {p420-p420}, DOI = {10.1093/europace/euaa162.018}, keywords = {atrial fibrillation, ultrasonography, balloon dilatation atrium ventricular tachycardia, induced heart valve bioprosthesis stenosis conscious sedation pulmonary veins freezing sinus rhythm catheters medical devices ablation}, doi = {10.1093/europace/euaa162.018}, title = {Improved real time recordings using the third generation cryoballoon technology - detection of dual fascicle electrograms}, keyword = {atrial fibrillation, ultrasonography, balloon dilatation atrium ventricular tachycardia, induced heart valve bioprosthesis stenosis conscious sedation pulmonary veins freezing sinus rhythm catheters medical devices ablation}, publisherplace = {online} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font