Pregled bibliografske jedinice broj: 1066123
Verification of the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) reference values in Croatian children and adolescents
Verification of the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) reference values in Croatian children and adolescents // Biochemia medica: the journal of The Croatian Society of Medical Biochemistry and Laboratory Medicine, 30 (2020), 2; 1-8 doi:10.11613/BM.2020.020710 (međunarodna recenzija, članak, stručni)
CROSBI ID: 1066123 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Verification of the Canadian Laboratory Initiative on Paediatric Reference
Intervals (CALIPER) reference values in Croatian children and adolescents
Autori
Zrinski Topic, Renata ; Leniček Krleža, Jasna
Izvornik
Biochemia medica: the journal of The Croatian Society of Medical Biochemistry and Laboratory Medicine (1330-0962) 30
(2020), 2;
1-8
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni
Ključne riječi
hormone ; immunoassay ; paediatric ; reference value
Sažetak
Introduction The aim of this study was to examine whether the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) could be applied to Croatian children and adolescents. Materials and methods A total of 295 outpatient healthy children and adolescents of age 1 to 18 were selected using the direct a posteriori sampling method. According to current guidelines, 20 samples were tested for each of a total of 51 reference intervals for ferritin, cortisol, dehydroepiandrosterone sulfate, follicle stimulating hormone, lutein stimulating hormone, prolactin, progesterone, sex hormone binding globulin, thyroid stimulating hormone, total testosterone, total thyroxine and total triiodothyronine. Serum samples were analysed on the Beckman Coulter DxI600 immunoassay analyser by chemiluminescence immunoassay method. A reference interval was adopted if < 10% of the results fall outside CALIPER reference interval range. For analytes in which this criterion is not met in the first set of samples, a new set of 20 samples were collected. Results After the first set of measurements, 96% of all tested reference intervals were adopted for use. The additional sets of 20 reference subjects were tested for only two reference intervals ; follicle stimulating hormone for female aged 1 to 9 years, and irrespective of the gender, sex hormone binding globulin for children aged 8 to 11 years. All results of additional samples were within the specified interval limits. Conclusions CALIPER reference intervals for ferritin and 11 hormones defined for Beckman Coulter DxI600 immunoassay analyser can be implemented into the Croatian laboratories and clinical practice.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Integrativna bioetika (prirodne, tehničke, biomedicina i zdravstvo, biotehničke, društvene, humanističke znanosti), Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)
POVEZANOST RADA
Ustanove:
Klinika za dječje bolesti
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE