Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences // Knjiga sažetaka XXIV hrvatskog skupa kemičara i kemijskih inženjera / Ukić, Šime ; Bolanča, Tomislav (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2015. str. 163-163 (poster, domaća recenzija, sažetak, znanstveni)


CROSBI ID: 1061035 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences

Autori
Raič, Irena ; Bešić, Denis ; Meštrović, Ernest

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Knjiga sažetaka XXIV hrvatskog skupa kemičara i kemijskih inženjera / Ukić, Šime ; Bolanča, Tomislav - Zagreb : Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2015, 163-163

ISBN
978-953-6894-54-3

Skup
XXIV. hrvatski skup kemičara i kemijskih inženjera

Mjesto i datum
Zagreb, Hrvatska, 21.04.2015. - 24.04.2015

Vrsta sudjelovanja
Poster

Vrsta recenzije
Domaća recenzija

Ključne riječi
Fe ; interferences ; ICP-MS

Sažetak
Due to the fact that Iron is common in any environment, including the laboratory equipment, tools and inventory, it represents great challenge for trace Iron (Fe) analysis, especially in active pharmceutical ingredient samples. This study was conducted to determine Fe contamination and to provide adequate method for wet etching of supposedly clean laboratory glassware. Iron adhered tenaciously to glassware that had been well washed and rinsed by usual methods (detergent, HNO3 and distilled water) and was removed only by washing the glassware with combination of acids (with Aqua Regia and also with combination of HCl:H2O2:deionized water at a ratio of 1:1:5). Variability sometimes noted in Fe determinations could possibly be attributed to Fe contamination on glassware. Our data showed that glassware should be washed with an appropriate acides mixture before subsequent determinations of Fe. Although ICP-MS is a powerful multi-element analytical technique, it does suffer from some welldocumented spectral interferences, which can be especially problematic when complex and variable samples are analyzed. These interferents are major reasons that less abundant isotopes of Fe are utilized in their respective analyses, which directly results with lower sensitivities and thus higher detection limits. The use of He collision mode provides a unique mode of operation, in which all the isotopes become detectable. The object of this study provides adequate method for overcoming contaminations, matrix and polyatomic interferences and presents parameters of a method for successfull Fe determination by using ICP-MS hellium collision gas mode.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
PLIVA HRVATSKA d.o.o.

Profili:

Avatar Url Ernest Meštrović (autor)

Avatar Url Irena Radić (autor)


Citiraj ovu publikaciju:

Raič, Irena; Bešić, Denis; Meštrović, Ernest
Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences // Knjiga sažetaka XXIV hrvatskog skupa kemičara i kemijskih inženjera / Ukić, Šime ; Bolanča, Tomislav (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2015. str. 163-163 (poster, domaća recenzija, sažetak, znanstveni)
Raič, I., Bešić, D. & Meštrović, E. (2015) Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences. U: Ukić, Š. & Bolanča, T. (ur.)Knjiga sažetaka XXIV hrvatskog skupa kemičara i kemijskih inženjera.
@article{article, author = {Rai\v{c}, Irena and Be\v{s}i\'{c}, Denis and Me\v{s}trovi\'{c}, Ernest}, year = {2015}, pages = {163-163}, keywords = {Fe, interferences, ICP-MS}, isbn = {978-953-6894-54-3}, title = {Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences}, keyword = {Fe, interferences, ICP-MS}, publisher = {Hrvatsko dru\v{s}tvo kemijskih in\v{z}enjera i tehnologa (HDKI)}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Rai\v{c}, Irena and Be\v{s}i\'{c}, Denis and Me\v{s}trovi\'{c}, Ernest}, year = {2015}, pages = {163-163}, keywords = {Fe, interferences, ICP-MS}, isbn = {978-953-6894-54-3}, title = {Fe determination by inductively coupled plasma mass spectrometry - overcoming contamination, matrix and polyatomic interferences}, keyword = {Fe, interferences, ICP-MS}, publisher = {Hrvatsko dru\v{s}tvo kemijskih in\v{z}enjera i tehnologa (HDKI)}, publisherplace = {Zagreb, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font