Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance


Grošev, Darko; Lončarić, Srećko; Vandenberghe Stefaan; Dodig, Damir
Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance // Fourth international congress of the croatian society of nuclear medicine
Opatija, Hrvatska, 2002. (predavanje, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 105528 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance

Autori
Grošev, Darko ; Lončarić, Srećko ; Vandenberghe Stefaan ; Dodig, Damir

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Skup
Fourth international congress of the croatian society of nuclear medicine

Mjesto i datum
Opatija, Hrvatska, 12.05.2002. - 15.05.2002

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
triple-head coincidence imaging; gamma camera PET; performance characteristics; sensitivity

Sažetak
Positron emission tomography (PET) is currently performed using either dedicated PET scanner or gamma camera equipped with electronic circuitry for coincidence detection of 511 keV annihilation quanta (gamma camera PET system). While resolution limits of these two instruments are comparable, sensitivity and count rate performance of the gamma camera PET system is several times lower than that of the PET scanner. Most gamma camera PET systems are manufactured as dual-detector systems capable of performing dual-head coincidence imaging. This work investigates performance characteristics of triple-head gamma camera PET system and compares them with 2-head system. Following performance characteristics of the system were assessed: spatial resolution, sensitivity, count rate performance. Spatial resolution, expressed as full-width-at-half-maximum (FWHM), at 1 cm radius is 5.9 mm ; at 10 cm radius transverse radial resolution is 5.3 mm while transverse tangential and axial resolution are 8.9 mm and 13.3 mm respectively. Sensitivity for standard cylindrical phantom is 255 c×s-1×MBq-1, cşcounts, using 30%-width photopeak energy window. Increase of 35 % in the PET sensitivity is achievable by opening an additional 30%-width energy window in the Compton region. Count rate in coincidence mode, at the upper limit of system&#8217 ; s optimal performance, is 45 kc×s-1 using only photopeak energy window, and increases to 60 kc×s-1 when using photopeak + Compton windows. Resolution when imaging cold phantom objects (rods and spheres) is 10 mm. In conclusion, our triple-head gamma camera PET system has system sensitivity two times higher in comparison with a similar dual-head system. Spatial resolution is in the same range as in the most dual-head systems.

Izvorni jezik
Engleski

Znanstvena područja
Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
214008

Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Srećko Lončarić (autor)

Avatar Url Darko Grošev (autor)

Avatar Url Damir Dodig (autor)


Citiraj ovu publikaciju:

Grošev, Darko; Lončarić, Srećko; Vandenberghe Stefaan; Dodig, Damir
Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance // Fourth international congress of the croatian society of nuclear medicine
Opatija, Hrvatska, 2002. (predavanje, međunarodna recenzija, sažetak, znanstveni)
Grošev, D., Lončarić, S., Vandenberghe Stefaan & Dodig, D. (2002) Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance. U: Fourth international congress of the croatian society of nuclear medicine.
@article{article, author = {Gro\v{s}ev, Darko and Lon\v{c}ari\'{c}, Sre\'{c}ko and Dodig, Damir}, year = {2002}, keywords = {triple-head coincidence imaging, gamma camera PET, performance characteristics, sensitivity}, title = {Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance}, keyword = {triple-head coincidence imaging, gamma camera PET, performance characteristics, sensitivity}, publisherplace = {Opatija, Hrvatska} }
@article{article, author = {Gro\v{s}ev, Darko and Lon\v{c}ari\'{c}, Sre\'{c}ko and Dodig, Damir}, year = {2002}, keywords = {triple-head coincidence imaging, gamma camera PET, performance characteristics, sensitivity}, title = {Triple-head coincidence imaging with gamma camera PET system: spatial resolution, sensitivity and count rate performance}, keyword = {triple-head coincidence imaging, gamma camera PET, performance characteristics, sensitivity}, publisherplace = {Opatija, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font