Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1052957

Effect of pulmonary hyperinflation on central blood volume : An MRI study


Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria; Barak, Otto F.; Drviš, Ivan; Secher Niels H.; Dujić, Željko; Madsen, Per Lav
Effect of pulmonary hyperinflation on central blood volume : An MRI study // Respiratory physiology & neurobiology, 243 (2017), 92-96 doi:10.1016/j.resp.2017.05.012 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1052957 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Effect of pulmonary hyperinflation on central blood volume : An MRI study

Autori
Mijacika, Tanja ; Kyhl, Kasper ; Frestad, Daria ; Barak, Otto F. ; Drviš, Ivan ; Secher Niels H. ; Dujić, Željko ; Madsen, Per Lav

Izvornik
Respiratory physiology & neurobiology (1569-9048) 243 (2017); 92-96

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Pulmonary hyperinflation ; Central blood volume ; Breath-hold diving ; Magnetic resonance imaging ; Central hypovolemia

Sažetak
Pulmonary hyperinflation attained by glossopharyngeal insufflation (GPI) challenges the circulation by compressing the heart and pulmonary vasculature. Our aim was to determine the amount of blood translocated from the central blood volume during GPI. Cardiac output and cardiac chamber volumes were assessed by magnetic resonance imaging in twelve breath- hold divers at rest and during apnea with GPI. Pulmonary blood volume was determined from pulmonary blood flow and transit times for gadolinium during first-pass perfusion after intravenous injection. During GPI, the lung volume increased by 0.8 ± 0.6 L (11 ± 7%) above the total lung capacity. All cardiac chambers decreased in volume and despite a heart rate increase of 24 ± 29 bpm (39 ± 50%), pulmonary blood flow decreased by 2783 ± 1820 mL (43 ± 20%). The pulmonary transit time remained unchanged at 7.5 ± 2.2 s and pulmonary blood volume decreased by 354 ± 176 mL (47 ± 15%). In total, central blood volume decreased by 532 ± 248 mL (46 ± 14%). Voluntary pulmonary hyperinflation leads to ∼50% decrease in pulmonary and central blood volume.

Izvorni jezik
Engleski

Znanstvena područja
Kineziologija



POVEZANOST RADA


Ustanove:
Kineziološki fakultet, Zagreb

Profili:

Avatar Url Željko Dujić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria; Barak, Otto F.; Drviš, Ivan; Secher Niels H.; Dujić, Željko; Madsen, Per Lav
Effect of pulmonary hyperinflation on central blood volume : An MRI study // Respiratory physiology & neurobiology, 243 (2017), 92-96 doi:10.1016/j.resp.2017.05.012 (međunarodna recenzija, članak, znanstveni)
Mijacika, T., Kyhl, K., Frestad, D., Barak, O., Drviš, I., Secher Niels H., Dujić, Ž. & Madsen, P. (2017) Effect of pulmonary hyperinflation on central blood volume : An MRI study. Respiratory physiology & neurobiology, 243, 92-96 doi:10.1016/j.resp.2017.05.012.
@article{article, author = {Mijacika, Tanja and Kyhl, Kasper and Frestad, Daria and Barak, Otto F. and Drvi\v{s}, Ivan and Duji\'{c}, \v{Z}eljko and Madsen, Per Lav}, year = {2017}, pages = {92-96}, DOI = {10.1016/j.resp.2017.05.012}, keywords = {Pulmonary hyperinflation, Central blood volume, Breath-hold diving, Magnetic resonance imaging, Central hypovolemia}, journal = {Respiratory physiology and neurobiology}, doi = {10.1016/j.resp.2017.05.012}, volume = {243}, issn = {1569-9048}, title = {Effect of pulmonary hyperinflation on central blood volume : An MRI study}, keyword = {Pulmonary hyperinflation, Central blood volume, Breath-hold diving, Magnetic resonance imaging, Central hypovolemia} }
@article{article, author = {Mijacika, Tanja and Kyhl, Kasper and Frestad, Daria and Barak, Otto F. and Drvi\v{s}, Ivan and Duji\'{c}, \v{Z}eljko and Madsen, Per Lav}, year = {2017}, pages = {92-96}, DOI = {10.1016/j.resp.2017.05.012}, keywords = {Pulmonary hyperinflation, Central blood volume, Breath-hold diving, Magnetic resonance imaging, Central hypovolemia}, journal = {Respiratory physiology and neurobiology}, doi = {10.1016/j.resp.2017.05.012}, volume = {243}, issn = {1569-9048}, title = {Effect of pulmonary hyperinflation on central blood volume : An MRI study}, keyword = {Pulmonary hyperinflation, Central blood volume, Breath-hold diving, Magnetic resonance imaging, Central hypovolemia} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font