Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads


Senjanović, Ivo; Vladimir, Nikola
Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads, 2020. (ekspertiza).


CROSBI ID: 1050778 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads

Autori
Senjanović, Ivo ; Vladimir, Nikola

Izvornik
Sveučilište u Zagrebu, Fakultet strojarstva i brodogradnje

Vrsta, podvrsta
Ostale vrste radova, ekspertiza

Godina
2020

Ključne riječi
Diesel generator set ; Base frame ; Elastic supports ; Nuclear Power Plant ; Static loading ; Seismic loading ; Short circuit ; Synchronization fault ; Finite Element Method

Sažetak
Structural integrity of diesel generator base frame subjected to combinations of static, seismic, short circuit and synchronization fault loadings has been evaluated. The diesel generator set will be installed in the Ruppur Nuclear Power Plant Energetic Blocks 1 & 2 in Bangladesh. Based on the documentation provided by the Client, the Finite Element (FE) model has been generated. Natural vibration analysis, static analysis and forced vibration analysis were performed. Special attention was paid to seismic loading, where random time series of its components have been generated. Also, the structure response to 2- phase short circuit as well as synchronization failure is calculated. Number of necessary elastic supports has been defined and their strength has been checked. Relevant stresses in elastic springs were determined by analytical formulae, while FEM is used to determine von Mises stresses in the complete base frame structure. The calculated stresses are compared with the allowable values. Finally, appropriate design of the whole system (diesel generator set, base frame and elastic supports) was proposed for relevant load combinations and required safety factors.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo

Napomena
Elaborat je izrađen za potrebe tvrtke Adriadiesel d.d., Karlovac.



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Ivo Senjanović (autor)

Avatar Url Nikola Vladimir (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Senjanović, Ivo; Vladimir, Nikola
Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads, 2020. (ekspertiza).
Senjanović, I. & Vladimir, N. (2020) Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads. Sveučilište u Zagrebu, Fakultet strojarstva i brodogradnje. Ekspertiza.
@unknown{unknown, author = {Senjanovi\'{c}, Ivo and Vladimir, Nikola}, year = {2020}, keywords = {Diesel generator set, Base frame, Elastic supports, Nuclear Power Plant, Static loading, Seismic loading, Short circuit, Synchronization fault, Finite Element Method}, title = {Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads}, keyword = {Diesel generator set, Base frame, Elastic supports, Nuclear Power Plant, Static loading, Seismic loading, Short circuit, Synchronization fault, Finite Element Method} }
@unknown{unknown, author = {Senjanovi\'{c}, Ivo and Vladimir, Nikola}, year = {2020}, keywords = {Diesel generator set, Base frame, Elastic supports, Nuclear Power Plant, Static loading, Seismic loading, Short circuit, Synchronization fault, Finite Element Method}, title = {Evaluation of structural integrity of diesel generator base frame and its elastic supports subjected to static and dynamic loads}, keyword = {Diesel generator set, Base frame, Elastic supports, Nuclear Power Plant, Static loading, Seismic loading, Short circuit, Synchronization fault, Finite Element Method} }