Pregled bibliografske jedinice broj: 1049763
Extension of the International Atomic Energy Agency phantom study in image quantification
Extension of the International Atomic Energy Agency phantom study in image quantification // Nuclear medicine communications, 39 (2018), 8; 797-802 doi:10.1097/mnm.0000000000000877 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1049763 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Extension of the International Atomic Energy Agency phantom study in image quantification
Autori
Grošev, Darko ; Gregov, Marin ; Wolfl, Miroslava Radić ; Krstonošić, Branislav ; Debeljuh, Dea Dundara
Izvornik
Nuclear medicine communications (0143-3636) 39
(2018), 8;
797-802
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
nuclear energy ; phantoms, imaging ; quality control
Sažetak
To make quantitative methods of nuclear medicine more available, four centres in Croatia participated in the national intercomparison study, following the materials and methods used in the previous international study organized by the International Atomic Energy Agency (IAEA). The study task was to calculate the activities of four Ba sources (T 1/2=10.54 years ; E γ=356 keV) using planar and single-photon emission computed tomography (SPECT) or SPECT/CT acquisitions of the sources inside a water-filled cylindrical phantom. The sources were previously calibrated by the US National Institute of Standards and Technology. Triple-energy window was utilized for scatter correction. Planar studies were corrected for attenuation correction (AC) using the conjugate-view method. For SPECT/CT studies, data from X-ray computed tomography were used for attenuation correction (CT-AC), whereas for SPECT-only acquisition, the Chang-AC method was applied. Using the lessons learned from the IAEA study, data were acquired according to the harmonized data acquisition protocol, and the acquired images were then processed using centralized data analysis. The accuracy of the activity quantification was evaluated as the ratio R between the calculated activity and the value obtained from National Institute of Standards and Technology. For planar studies, R=1.06±0.08 ; for SPECT/CT study using CT-AC, R=1.00±0.08 ; and for Chang-AC, R=0.89±0.12. The results are in accordance with those obtained within the larger IAEA study and confirm that SPECT/CT method is the most appropriate for accurate activity quantification
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinički bolnički centar Osijek,
KBC "Sestre Milosrdnice",
Klinički bolnički centar Zagreb,
Klinički bolnički centar Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE