Changes in endothelial cell count up to three years after implantation of toric implantable collamer lenses
Changes in endothelial cell count up to three years after implantation of toric implantable collamer lenses // Cornea, 38 (2019), 7; 873-879 doi:10.1097/ico.0000000000001914 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1048544 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Changes in endothelial cell count up to three years after implantation of toric implantable collamer lenses
Autori
Bohač, Maja ; Jagić, Mateja ; Biščević, Alma ; Shijakova, Violeta ; Gabrić, Nikica ; Patel, Sudi
Izvornik
Cornea (0277-3740) 38
(2019), 7;
873-879
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
implantable collamer lens ; endothelial cell density ; myopic astigmatism, phakic intraocular-lens ; 4-year follow-up ; long-term ; high myopia ; american-academy ; anterior segment ; moderate ; model ; eyes ; hole
Sažetak
To determine the temporal effect of toric implantable collamer lens (TICL) implantation and location on corneal endothelial cell density (ECD) over a period of 36 months after surgery. Methods: ECD [number of cells per square millimeter estimated using the Specular Microscope SP-1P (Topcon Europe Medical B. V., Netherlands)] data were collected from cases deemed suitable for the TICL (VTICMO, VTICM5 ; STAAR Surgical, Nidau, Switzerland). The preoperative refractive error (sphere and cylinder) ranged from -1.00 to -22.25 diopter sphere and from 20.50 to -5.50 diopter cylinder. ECD was evaluated at preoperative and all postoperative sessions. Key findings were as follows: the mean ECD (6SD, 95% confidence interval) was 2720 cells/mm(2) (6272, 2620-2820 cells/mm(2)) preoperatively, which was reduced to 2372 cells/mm(2) (+/-325, 2250-2490 cells/mm(2)) at 36 months postoperatively (P, 0.001). Linear regression revealed the following significant correlations between the (1) log of the change in ECD (y(1)) and log of preoperative ECD (x(1)) at 2 years postoperatively, y(1) =2.513x(1)-6.2816 (n=62, r=0.3503, P =0.005) ; (2) mean ECD (y(2)) and log time (in months, x(2)), y(2)=2543.7- 36.997x(2)-38.99x(2) 2 (r=20.9654, n =7, P = 0.0004) ; and (3) mean axial distance between the front surface of the crystalline lens and the TICL back surface (y3) and time postoperatively (in months, x(3)), y(3) =0.1035x3 225.2808x(3) + 473.18 (r =0.8512, n =7, P =0.015). Expected ECD loss after TICL implantation by 2 years postoperatively is predictable. On average, over 3 years after implantation, there is (1) an initial rapid decline in ECD, followed by a gradual fall in the rate of cell loss, and (2) a gradual fall in the distance between the TICL and the crystalline lens by 2 years postoperatively, followed by a reversal by the third year.
Izvorni jezik
Engleski
Znanstvena područja
Grafička tehnologija
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE