Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1045303

Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard?


Lapić, Ivana; Piva, Elisa; Spolaore, Federica; Musso, Giulia; Tosato, Francesca; Pelloso, Michela; Plebani, Mario
Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard? // Journal of clinical pathology, 72 (2019), 10; 1-4 doi:10.1136/jclinpath-2019-205873 (međunarodna recenzija, članak, stručni)


CROSBI ID: 1045303 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard?

Autori
Lapić, Ivana ; Piva, Elisa ; Spolaore, Federica ; Musso, Giulia ; Tosato, Francesca ; Pelloso, Michela ; Plebani, Mario

Izvornik
Journal of clinical pathology (0021-9746) 72 (2019), 10; 1-4

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni

Ključne riječi
erythroctye sedimentation rate ; Ves-Matic CUBE 200 ; Westergren ; precision ; comparison

Sažetak
Ves-Matic CUBE 200 is an automated erythrocyte sedimentation rate (ESR) analyser based on the modified Westergren principle of measurement. In this study, we aimed to assess its analytical performance following the key points addressed by the International Council for Standardization in Haematology and the comparability with the gold standard Westergren method. Comparison of the two methods yielded a correlation coefficient of 0.852, no significant bias and a small constant difference between compared results. Intrarun coefficients of variation (CV) ranged from 2.2% to 22.2%, the higher being for lower ESR values, while inter-run CVs were 19.7% for the normal range and 3.0% for the abnormal range. This study proved the analytical validity of the Ves-Matic CUBE 200 and its high comparability with the Westergren method, showing obvious improvements in the technology applied for automated determination of ESR and a valuable step forward in standardisation of ESR methods.

Izvorni jezik
Engleski

Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Profili:

Avatar Url Ivana Lapić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Lapić, Ivana; Piva, Elisa; Spolaore, Federica; Musso, Giulia; Tosato, Francesca; Pelloso, Michela; Plebani, Mario
Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard? // Journal of clinical pathology, 72 (2019), 10; 1-4 doi:10.1136/jclinpath-2019-205873 (međunarodna recenzija, članak, stručni)
Lapić, I., Piva, E., Spolaore, F., Musso, G., Tosato, F., Pelloso, M. & Plebani, M. (2019) Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard?. Journal of clinical pathology, 72 (10), 1-4 doi:10.1136/jclinpath-2019-205873.
@article{article, author = {Lapi\'{c}, Ivana and Piva, Elisa and Spolaore, Federica and Musso, Giulia and Tosato, Francesca and Pelloso, Michela and Plebani, Mario}, year = {2019}, pages = {1-4}, DOI = {10.1136/jclinpath-2019-205873}, keywords = {erythroctye sedimentation rate, Ves-Matic CUBE 200, Westergren, precision, comparison}, journal = {Journal of clinical pathology}, doi = {10.1136/jclinpath-2019-205873}, volume = {72}, number = {10}, issn = {0021-9746}, title = {Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard?}, keyword = {erythroctye sedimentation rate, Ves-Matic CUBE 200, Westergren, precision, comparison} }
@article{article, author = {Lapi\'{c}, Ivana and Piva, Elisa and Spolaore, Federica and Musso, Giulia and Tosato, Francesca and Pelloso, Michela and Plebani, Mario}, year = {2019}, pages = {1-4}, DOI = {10.1136/jclinpath-2019-205873}, keywords = {erythroctye sedimentation rate, Ves-Matic CUBE 200, Westergren, precision, comparison}, journal = {Journal of clinical pathology}, doi = {10.1136/jclinpath-2019-205873}, volume = {72}, number = {10}, issn = {0021-9746}, title = {Ves-Matic CUBE 200: Is Modified Westergren Method for Erythrocyte Sedimentation Rate a Valid Alternative to the Gold Standard?}, keyword = {erythroctye sedimentation rate, Ves-Matic CUBE 200, Westergren, precision, comparison} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font