Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1039699

The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker


Plavec, Eduard; Filipović-Grčić, Božidar; Vidović, Mladen
The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker // International journal of electrical power & energy systems, 118C (2020), 1-7 doi:10.1016/j.ijepes.2019.105767 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1039699 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker

Autori
Plavec, Eduard ; Filipović-Grčić, Božidar ; Vidović, Mladen

Izvornik
International journal of electrical power & energy systems (0142-0615) 118C (2020); 1-7

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Electromagnetic actuator ; Plunger angle ; Plunger radius ; Time response

Sažetak
This paper presents the research on the impact of plunger angle on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker (HVCB). The research method is based on analytical analysis of the magnetic path of DC solenoid electromagnetic actuator and comparison with the numerical simulation results. Transient numerical simulation of DC electromagnetic actuator has been performed on 2D axial- symmetric model using finite element method (FEM). Numerical simulation includes simultaneously solving differential equations of magnetic, electrical and mechanical subsystems. The electrical and mechanical subsystems are modelled separately and then mutually coupled with the magnetic subsystem which is analysed by FEM in ANSYS Electronics software package. The measurement results obtained after the production and laboratory testing of electromagnetic actuators with different plunger angles are compared with the analytical and numerical simulation results.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika

Napomena
Full paper can be donwloaded from the following link: https://authors.elsevier.com/c/1aHar_3EkWexm0



POVEZANOST RADA


Ustanove:
KONČAR - Institut za elektrotehniku d.d.,
Fakultet elektrotehnike i računarstva, Zagreb

Citiraj ovu publikaciju:

Plavec, Eduard; Filipović-Grčić, Božidar; Vidović, Mladen
The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker // International journal of electrical power & energy systems, 118C (2020), 1-7 doi:10.1016/j.ijepes.2019.105767 (međunarodna recenzija, članak, znanstveni)
Plavec, E., Filipović-Grčić, B. & Vidović, M. (2020) The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker. International journal of electrical power & energy systems, 118C, 1-7 doi:10.1016/j.ijepes.2019.105767.
@article{article, author = {Plavec, Eduard and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and Vidovi\'{c}, Mladen}, year = {2020}, pages = {1-7}, DOI = {10.1016/j.ijepes.2019.105767}, keywords = {Electromagnetic actuator, Plunger angle, Plunger radius, Time response}, journal = {International journal of electrical power and energy systems}, doi = {10.1016/j.ijepes.2019.105767}, volume = {118C}, issn = {0142-0615}, title = {The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker}, keyword = {Electromagnetic actuator, Plunger angle, Plunger radius, Time response} }
@article{article, author = {Plavec, Eduard and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and Vidovi\'{c}, Mladen}, year = {2020}, pages = {1-7}, DOI = {10.1016/j.ijepes.2019.105767}, keywords = {Electromagnetic actuator, Plunger angle, Plunger radius, Time response}, journal = {International journal of electrical power and energy systems}, doi = {10.1016/j.ijepes.2019.105767}, volume = {118C}, issn = {0142-0615}, title = {The impact of plunger angle and radius on the force and time response of DC solenoid electromagnetic actuator used in high-voltage circuit breaker}, keyword = {Electromagnetic actuator, Plunger angle, Plunger radius, Time response} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font