Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1039390

The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players


Jeličić, Mario; Ivančev, Vladimir; Čular, Dražen; Čović, Nedim; Stojanović, Emilija; Scanlan, Aaron T.; Milanović, Zoran
The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players // Research quarterly for exercise and sport, 91 (2020), 1; 83-91 doi:10.1080/02701367.2019.1648743 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1039390 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players

Autori
Jeličić, Mario ; Ivančev, Vladimir ; Čular, Dražen ; Čović, Nedim ; Stojanović, Emilija ; Scanlan, Aaron T. ; Milanović, Zoran

Izvornik
Research quarterly for exercise and sport (0270-1367) 91 (2020), 1; 83-91

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
VO(2)max ; endurance ; fitness ; women

Sažetak
Purpose: The purpose of this study was to determine the reliability, validity, and usefulness of 30?15 Intermittent Fitness Test (30- 15(IFT)) in female basketball players. Methods: Nineteen female basketball players (17.82 ? 1.94 yr, 175.4 ? 7.3 cm, 67.9 ? 7.7 kg) competing in the National Croatian League performed one trial of a continuous treadmill running test and two trials of the 30-15(IFT). The 30-15(IFT) involves 30-s runs across a 40-m course interspersed with 15 s of walking, with running speed increasing every 45 s. The continuous treadmill running test was used as the criterion for validation. Results: High to very high reliability across test?retest trials were observed for maximal oxygen uptake (VO(2)max) (CV = 4.9%, ICC = 0.85), the 30-15(IFT) end-running velocity (V-IFT) (CV = 6.0%, ICC = 0.85), and maximal heart rate (HRmax) (CV = 4.8%, ICC = 0.96). Criterion validity was supported for the 30-15(IFT) with strong to very strong relationships with VO(2)max (r =0.69), V-IFT (r =0.74), and HRmax (r =0.73) attained during the continuous treadmill running test. The typical error (TE) of the 30-15(IFT) was greater than the smallest worthwhile change for VO(2)max (1.16 > 0.42 ml/kg/min), V-IFT (0.56 > 0.20 km/h), and HRmax (2.15 > 1.89 bpm) adjudging usefulness of the test as marginal. The TE of 0.56 km/h (90% CI = 0.44?0.77 km/h) demonstrates changes in the performance of one to two stages (0.5?1.0 km/h) are meaningful. Conclusions: The 30-15(IFT) possesses acceptable reliability and validity to assess maximal aerobic fitness capacity in female basketball players. While the usefulness of the 30-15(IFT) was marginal, meaningful changes in performance consisted of only one to two stages. The present findings support the 30-15(IFT) as a practical testing option for basketball practitioners to assess fitness capacities in female players.

Izvorni jezik
Engleski

Znanstvena područja
Kineziologija



POVEZANOST RADA


Ustanove:
Kineziološki fakultet, Split

Profili:

Avatar Url Dražen Čular (autor)

Avatar Url Vladimir Ivančev (autor)

Avatar Url Mario Jeličić (autor)

Poveznice na cjeloviti tekst rada:

doi www.tandfonline.com

Citiraj ovu publikaciju:

Jeličić, Mario; Ivančev, Vladimir; Čular, Dražen; Čović, Nedim; Stojanović, Emilija; Scanlan, Aaron T.; Milanović, Zoran
The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players // Research quarterly for exercise and sport, 91 (2020), 1; 83-91 doi:10.1080/02701367.2019.1648743 (međunarodna recenzija, članak, znanstveni)
Jeličić, M., Ivančev, V., Čular, D., Čović, N., Stojanović, E., Scanlan, A. & Milanović, Z. (2020) The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players. Research quarterly for exercise and sport, 91 (1), 83-91 doi:10.1080/02701367.2019.1648743.
@article{article, author = {Jeli\v{c}i\'{c}, Mario and Ivan\v{c}ev, Vladimir and \v{C}ular, Dra\v{z}en and \v{C}ovi\'{c}, Nedim and Stojanovi\'{c}, Emilija and Scanlan, Aaron T. and Milanovi\'{c}, Zoran}, year = {2020}, pages = {83-91}, DOI = {10.1080/02701367.2019.1648743}, keywords = {VO(2)max, endurance, fitness, women}, journal = {Research quarterly for exercise and sport}, doi = {10.1080/02701367.2019.1648743}, volume = {91}, number = {1}, issn = {0270-1367}, title = {The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players}, keyword = {VO(2)max, endurance, fitness, women} }
@article{article, author = {Jeli\v{c}i\'{c}, Mario and Ivan\v{c}ev, Vladimir and \v{C}ular, Dra\v{z}en and \v{C}ovi\'{c}, Nedim and Stojanovi\'{c}, Emilija and Scanlan, Aaron T. and Milanovi\'{c}, Zoran}, year = {2020}, pages = {83-91}, DOI = {10.1080/02701367.2019.1648743}, keywords = {VO(2)max, endurance, fitness, women}, journal = {Research quarterly for exercise and sport}, doi = {10.1080/02701367.2019.1648743}, volume = {91}, number = {1}, issn = {0270-1367}, title = {The 30-15 Intermittent Fitness Test: A Reliable, Valid, and Useful Tool to Assess Aerobic Capacity in Female Basketball Players}, keyword = {VO(2)max, endurance, fitness, women} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • Social Science Citation Index (SSCI)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font