Pregled bibliografske jedinice broj: 1037252
Effect of structure stiffness on seismic base isolation efficiency using natural stone pebbles
Effect of structure stiffness on seismic base isolation efficiency using natural stone pebbles // CD-ROM Proceedings of the abstracts of of 13th International Conference on Advanced Computational Engineering and Experimenting ACE-X 2019 / Öchsner, Andreas ; Altenbach, Holm ; Johlitz, Michael (ur.).
Atena, Grčka: ACEX - Advanced Computational Engineering and Experimenting, 2019. str. 38-38 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 1037252 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Effect of structure stiffness on seismic base isolation efficiency using natural stone pebbles
Autori
Banović, Ivan ; Radnić, Jure ; Grgić, Nikola
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
CD-ROM Proceedings of the abstracts of of 13th International Conference on Advanced Computational Engineering and Experimenting ACE-X 2019
/ Öchsner, Andreas ; Altenbach, Holm ; Johlitz, Michael - : ACEX - Advanced Computational Engineering and Experimenting, 2019, 38-38
Skup
13th International Conference on Advanced Computational Engineering and Experimenting (ACE-X2019)
Mjesto i datum
Atena, Grčka, 01.07.2019. - 05.07.2019
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
seismic base isolation ; stone pebble layer ; effect of building stiffness ; shake-table testing
Sažetak
This paper presents the results of a shake-table study regarding the effect of structure stiffness on seismic base isolation efficiency using natural stone pebbles layer. Case studies were conducted with four different structure stiffness (M1, M2, M3, and M4) with the foundation of model on the rigid base and on two different layers of pebbles (layer thickness hp= 0.3 m and hp= 0.6 m). The buildings were modelled with a cantilever column with a mass on top - SDOF, with fundamental period of free oscillation of the column T1, M1 = 0.05 s, T1, M2 = 0.30 s, T1, M3 = 0.60 s, and T1, M4 = 1.40 s, which corresponds to a very stiff, stiff, medium stiff and soft building. Four different horizontal accelerograms were applied, and strains/stresses of the tested models remained in the elastic area. Some specimens were exposed to a set of repeated horizontal base accelerations until structure collapse. For each test, the characteristic displacements, accelerations, and strains were measured. Only some most important study results are shown. It was concluded that the efficiency of seismic base isolation using a layer of natural stone pebbles significantly depends on the building stiffness.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo
POVEZANOST RADA
Projekti:
HRZZ-IP-2016-06-5325 - Seizmička izolacija osnove građevine s uporabom prirodnih materijala - testiranje s potresnom platformom i numeričko modeliranje (BASEISOLATION) (Radnić, Jure) ( CroRIS)
Ustanove:
Fakultet građevinarstva, arhitekture i geodezije, Split