High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter


Zeljkovic, Ivan; Knecht, Sven; Pavlovic, Nikola; Celikyrut, Umut; Spies, Florian; Burri, Sarah; Mannhart, Dominik; Peterhans, Loris; Reichlin, Tobias; Schaer, Beat et al.
High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter // Open Heart, 6 (2019), 1; 1-8 doi:10.1136/openhrt-2018-000949 (međunarodna recenzija, članak, ostalo)


CROSBI ID: 1031552 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter

Autori
Zeljkovic, Ivan ; Knecht, Sven ; Pavlovic, Nikola ; Celikyrut, Umut ; Spies, Florian ; Burri, Sarah ; Mannhart, Dominik ; Peterhans, Loris ; Reichlin, Tobias ; Schaer, Beat ; Osswald, Stefan ; Sticherling, Christian ; Kuhne, Michael

Izvornik
Open Heart (2053-3624) 6 (2019), 1; 1-8

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, ostalo

Ključne riječi
ablation ; atrial fibrillation ; complications ; creatine kinase ; creatine kinase-mb ; cryoballoon ; high-sensitive-troponin T ; nmarq ; pericarditis ; pulmonary vein isolation ; radiofrequency ; recurrence

Sažetak
INTRODUCTION: Myocardial injury markers such as high-sensitive cardiac troponin T (hs-cTnT) and creatine kinase MB (CK-MB) reflects the amount of myocardial injury with ablation. The aim of the study was to identify the value of myocardial injury markers to predict outcomes after pulmonary vein isolation (PVI) using three different ablation technologies. METHODS: Consecutive patients undergoing PVI using a standard 3.5 mm irrigated-tip radiofrequency catheter (RF-group), an irrigated multielectrode radiofrequency catheter (IMEA-group) and a second- generation cryoballoon (CB-group) were analysed. Blood samples to measure injury markers were taken before and 18-24 hours after the ablation. Procedural complications were collected and standardised follow-up was performed. Logistic regression was used to identify predictors of recurrence and complications. RESULTS: 96 patients (RF group: n=40, IMEA-group: n=17, CB-group: n=39) undergoing PVI only were analysed (82% male, age 59±10 years). After a follow-up of 12 months, atrial fibrillation (AF) recurred in 45% in the RF-group, 29% in the IMEA-group and 36% in the CB-group (p=0.492). Symptomatic pericarditis was observed in 20% of patients in the RF-group, 15% in the IMEA-group and 5% in the CB-group (p=0.131). None of the injury markers was predictive of AF recurrence or PV reconnection after a single procedure. However, hs-cTnT was identified as a predictor of symptomatic pericarditis (OR: 1.003 [1.001 to 1.005], p=0.015). CONCLUSION: Hs-cTnT and CK-MB were significantly elevated after PVI, irrespective of the ablation technology used. None of the myocardial injury markers were predictive for AF recurrence or PV reconnection, but hs-cTnT release predicts the occurrence of symptomatic pericarditis after PVI.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice"

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Zeljkovic, Ivan; Knecht, Sven; Pavlovic, Nikola; Celikyrut, Umut; Spies, Florian; Burri, Sarah; Mannhart, Dominik; Peterhans, Loris; Reichlin, Tobias; Schaer, Beat et al.
High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter // Open Heart, 6 (2019), 1; 1-8 doi:10.1136/openhrt-2018-000949 (međunarodna recenzija, članak, ostalo)
Zeljkovic, I., Knecht, S., Pavlovic, N., Celikyrut, U., Spies, F., Burri, S., Mannhart, D., Peterhans, L., Reichlin, T. & Schaer, B. (2019) High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter. Open Heart, 6 (1), 1-8 doi:10.1136/openhrt-2018-000949.
@article{article, author = {Zeljkovic, Ivan and Knecht, Sven and Pavlovic, Nikola and Celikyrut, Umut and Spies, Florian and Burri, Sarah and Mannhart, Dominik and Peterhans, Loris and Reichlin, Tobias and Schaer, Beat and Osswald, Stefan and Sticherling, Christian and Kuhne, Michael}, year = {2019}, pages = {1-8}, DOI = {10.1136/openhrt-2018-000949}, keywords = {ablation, atrial fibrillation, complications, creatine kinase, creatine kinase-mb, cryoballoon, high-sensitive-troponin T, nmarq, pericarditis, pulmonary vein isolation, radiofrequency, recurrence}, journal = {Open Heart}, doi = {10.1136/openhrt-2018-000949}, volume = {6}, number = {1}, issn = {2053-3624}, title = {High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter}, keyword = {ablation, atrial fibrillation, complications, creatine kinase, creatine kinase-mb, cryoballoon, high-sensitive-troponin T, nmarq, pericarditis, pulmonary vein isolation, radiofrequency, recurrence} }
@article{article, author = {Zeljkovic, Ivan and Knecht, Sven and Pavlovic, Nikola and Celikyrut, Umut and Spies, Florian and Burri, Sarah and Mannhart, Dominik and Peterhans, Loris and Reichlin, Tobias and Schaer, Beat and Osswald, Stefan and Sticherling, Christian and Kuhne, Michael}, year = {2019}, pages = {1-8}, DOI = {10.1136/openhrt-2018-000949}, keywords = {ablation, atrial fibrillation, complications, creatine kinase, creatine kinase-mb, cryoballoon, high-sensitive-troponin T, nmarq, pericarditis, pulmonary vein isolation, radiofrequency, recurrence}, journal = {Open Heart}, doi = {10.1136/openhrt-2018-000949}, volume = {6}, number = {1}, issn = {2053-3624}, title = {High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter}, keyword = {ablation, atrial fibrillation, complications, creatine kinase, creatine kinase-mb, cryoballoon, high-sensitive-troponin T, nmarq, pericarditis, pulmonary vein isolation, radiofrequency, recurrence} }