Reducing Data Center Power Losses through UPS Serial Consolidation
Reducing Data Center Power Losses through UPS Serial Consolidation // Proceedings of the 27th International Conference on Software, Telecommunications and Computer Networks (SoftCOM 2019) / Lorenz, Pascal ; Rožić, Nikola (ur.).
Split: Fakultet elektrotehnike, strojarstva i brodogradnje Sveučilišta u Splitu, 2019. str. 1-6 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1021466 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Reducing Data Center Power Losses through UPS Serial Consolidation
Autori
AL-Hazemi, Fawaz ; Lorincz, Josip ; Mohammed, Alaelddin Fuad Yousif ; Salamh, Fahad
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 27th International Conference on Software, Telecommunications and Computer Networks (SoftCOM 2019)
/ Lorenz, Pascal ; Rožić, Nikola - Split : Fakultet elektrotehnike, strojarstva i brodogradnje Sveučilišta u Splitu, 2019, 1-6
Skup
27th International Conference of Software, Telecommunications and Computer Networks (SoftCOM 2019)
Mjesto i datum
Split, Hrvatska, 19.09.2019. - 21.09.2019
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Data Center ; Power Delivery Path ; Management ; Virtual machine ; Server ; UPS ; Energy-efficiency ; Consolidation
Sažetak
Reducing data center (DC) power consumption is one of green Information and Communication Technology (ICT) challenges, which can be realised through improvement of DC energy-efficiency. To accomplish this improvement, each component of DC including those of power supply system such as uninterruptible power supplies (UPSs), has to operate at its maximum power efficiency. Since the broadly accepted concept based on server consolidation approach demonstrates significant DC power saving at the level of server racks, the contribution of constantly active UPSs to the overall DC power inefficiency become non-negligible. It is shown that a possible technique for reducing UPS power inefficiency in DCs can be based on dynamic merging of UPS activity state with server consolidation, where the neighbouring connectivity between one UPSs and two neighbour server racks have been established on the backup power supply paths. In this paper enhancement of neighbouring connectivity concept based on a new approach for establishing connectivity between UPSs and server racks on DC backup power delivery paths are introduced. More specifically, the algorithm which enables serial connectivity of active UPSs with DC server racks during merged UPS and server consolidation process is proposed. Through the extensive simulations of real DC having a large number of rack servers and UPSs, the proposed concept based on serial connectivity has been tested. Results show that proposed concept improves the energy-efficiency of DC when compared with neighbouring connectivity approach or existing legacy DC power supply approach lacking any UPS consolidation. Proposed concept can be used in practice as a solution which can reduce the impact of power consumption inefficiency of UPSs as main DC power supply elements.