Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1018752

THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING


Miletić, Manuela; Grubešić, Daniel
THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING // Clinical Chemistry and Laboratory Medicine 2019, 57(4):eA1-eA87
Zagreb, Hrvatska, 2019. str. eA26-eA26 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 1018752 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING

Autori
Miletić, Manuela ; Grubešić, Daniel

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Clinical Chemistry and Laboratory Medicine 2019, 57(4):eA1-eA87 / - , 2019, EA26-eA26

Skup
5th EFLM Conference on Preanalytical Phase

Mjesto i datum
Zagreb, Hrvatska, 22.03.2019. - 23.03.2019

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
cadaveric cornea donors, serological testing

Sažetak
Background: Serological testing of cadaveric cornea donors in Croatia includes HBsAg, anti-HCV, anti-HIV-1/2, anti-TP and anti-HBc (if positive, anti-HBs is performed). Cadaveric specimens are collected at variable times after death, often of poor quality (haemolysed or autolyzed) and frequently yield falsely positive results in serological testing. Although Abbott Architect assays (HBsAg Qualitative II, Anti-HCV, HIV Ag/Ab Combo, Syphilis TP and Anti-HBc II) are validated for cadaveric specimens, we found a lot of unspecific reactions and implemented confirmatory testing algorithms. Methods: From 2016 till October 2018, we got 643 different cadaveric specimens, from the Eye Bank – University Hospital Centre Zagreb. Initial tests used are named Abbott Architect tests. The following tests were used to decide on false or correct positive results: for HBsAg: Bio-Rad Monolisa HBsAg Ultra, Architect Confirmatory test, Vidas HBsAg ULTRA ; for anti-HCV: Vidas Anti-HCV, Bio-Rad Monolisa HCV Ag-Ab Ultra v2 Combo, immunoblot (Mikrogen and/or Fujirebio) ; for HIV Ag/Ab: Dia.Pro HIV Ab&Ag, Vidas HIV DUO ULTRA, immunoblot (Mikrogen and/or Fujirebio), Vidas HIV P24 ; for anti-TP: Dia.Pro Syphilis Ab v. ULTRA, TPHA, RPR, immunoblot (Mikrogen and/or Fujirebio), Dia.Pro Syphilis IgM ; for anti-HBc: Dia.Pro HBcAb and Vidas Anti-HBc Total II. Results: The total falsely positives of Architect tests were found in 3% (19/634) of HBsAg, 0.3% (2/634) of anti-HCV, 4.7% (30/634) of HIV Ag/Ab, 0.3% (2/634) of anti-TP and 0.6% (4/634) of anti-HBc results. Conclusions: The observed specificity data of the Architect tests used for the initial cadaveric specimen testing show that the highest proportion of falsely positive results is in HIV Ag/Ab test, then HBsAg, anti-HBc and anti-TP/anti-HCV, respectively. Implemented confirmation testing algorithms saved in given period the total of 57 corneas from needlessly discard and assure the supply and safety of corneas for transplantation.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Manuela Miletić (autor)


Citiraj ovu publikaciju:

Miletić, Manuela; Grubešić, Daniel
THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING // Clinical Chemistry and Laboratory Medicine 2019, 57(4):eA1-eA87
Zagreb, Hrvatska, 2019. str. eA26-eA26 (poster, međunarodna recenzija, sažetak, stručni)
Miletić, M. & Grubešić, D. (2019) THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING. U: Clinical Chemistry and Laboratory Medicine 2019, 57(4):eA1-eA87.
@article{article, author = {Mileti\'{c}, Manuela and Grube\v{s}i\'{c}, Daniel}, year = {2019}, pages = {eA26-eA26}, keywords = {cadaveric cornea donors, serological testing}, title = {THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING}, keyword = {cadaveric cornea donors, serological testing}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Mileti\'{c}, Manuela and Grube\v{s}i\'{c}, Daniel}, year = {2019}, pages = {eA26-eA26}, keywords = {cadaveric cornea donors, serological testing}, title = {THE POOR QUALITY OF CADAVERIC CORNEA SPECIMENS = A LOT OF FALSELY POSITIVE RESULTS IN SEROLOGICAL TESTING}, keyword = {cadaveric cornea donors, serological testing}, publisherplace = {Zagreb, Hrvatska} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font