Hybrid Method for Islanding Detection of Distributed Generators in LV Distribution Network
Hybrid Method for Islanding Detection of Distributed Generators in LV Distribution Network // Proceedings from 18th IEEE International Conference on Smart Technologies EUROCON 2019. / Dumić, Boris (ur.).
Novi Sad: GRID.FTN Novi Sad, 2019. 10228, 6 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1016976 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Hybrid Method for Islanding Detection of Distributed Generators in LV Distribution Network
Autori
Mlakič, Dragan ; Nikolovski, Srete ; Hamid Reza Baghaee
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings from 18th IEEE International Conference on Smart Technologies EUROCON 2019.
/ Dumić, Boris - Novi Sad : GRID.FTN Novi Sad, 2019
ISBN
978-86-6022-167-3
Skup
18th IEEE International Conference on Smart Technologies (EUROCON 2019)
Mjesto i datum
Novi Sad, Srbija, 01.07.2019. - 04.07.2019
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Islanding Detection, Inverter based generation, Rate of change of frequency, RMS rate of change, Power Quality
Sažetak
Islanding problem of DG-s in Distribution Network (DN) DGs. Simulation results shows precision with allowed comes with development and implementation of Renewable Energy Sources (RES) as Distributed Generator (DG). This research introduces new hybrid method for islanding detection of DC/AC inverter based DG in Low Voltage (LV) DN. Proposed technique is combination of active and passive technique: frequency change at given moment and rate of change of RMS voltage. Proposed method heavily exploit sinusoidal function interpolation due to Fourier transformation when Gibbs phenomenon occurs. To prove its effectiveness several test conducted based on different active load conditions and multiple impact on power quality according to standard EN 50160. Proposed method shows good results as in low power consumption regime thus in high power regime. Hybrid method gives Non Detection Zone (NDZ) smaller than individual islanding detection hybrid methods of frequency and under voltage based by combining those techniques as active and passive