Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1014313

Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material


Žauhar, Gordana; Smilović Radojčić, Đeni; Kaliman, Zoran; Schnurrer-Luke-Vrbanić, Tea; Jurković, Slaven
Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material // Ultrasonics, 99 (2019), 105943, 6 doi:10.1016/j.ultras.2019.06.005 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1014313 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material

Autori
Žauhar, Gordana ; Smilović Radojčić, Đeni ; Kaliman, Zoran ; Schnurrer-Luke-Vrbanić, Tea ; Jurković, Slaven

Izvornik
Ultrasonics (0041-624X) 99 (2019); 105943, 6

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
ultrasound therapy ; thermochromic material ; effective radiating area ; beam non - uniformity ratio

Sažetak
The evaluation of the performance of nine physiotherapy ultrasound transducers used clinically was performed in the hospital environment using an acoustically absorbing thermocromic tile developed at the National Physical Laboratory (UK). The method consists of exposing an acoustic absorber tile, part of which contains a thermochromic pigment, to the ultrasonic beam, thereby forming an image of the intensity profile of the transducer. Images acquired using thermochromic materials were postprocessed in order to estimate effective radiating area (ERA) and beam nonuniformity ratio (BNR) for ultrasound transducers operating within the frequency range from 1.0 to 3.3 MHz, and nominal applied intensities in the range of 1-2 W/cm2. Results of our measurements have shown that thermocromic tile can be used for quality control of ultrasound transducers in the hospital environment. Experimental results show that proposed method can be used to distinguish highly non - uniform ultrasound beams with high value of BNR. Influence of exposure duration on obtained ERA and BNR values was also analysed. Our results show that values for ERA increase with insonation time, while BNR values decrease. In order to compare our results with theory we have estimated temperature rise in thermochromic material experimentally and compare it with theoretical prediction.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Interdisciplinarne prirodne znanosti



POVEZANOST RADA


Projekti:
uniri-prirod-18-75

Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Rijeka,
Sveučilište u Rijeci - Odjel za fiziku

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Žauhar, Gordana; Smilović Radojčić, Đeni; Kaliman, Zoran; Schnurrer-Luke-Vrbanić, Tea; Jurković, Slaven
Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material // Ultrasonics, 99 (2019), 105943, 6 doi:10.1016/j.ultras.2019.06.005 (međunarodna recenzija, članak, znanstveni)
Žauhar, G., Smilović Radojčić, Đ., Kaliman, Z., Schnurrer-Luke-Vrbanić, T. & Jurković, S. (2019) Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material. Ultrasonics, 99, 105943, 6 doi:10.1016/j.ultras.2019.06.005.
@article{article, author = {\v{Z}auhar, Gordana and Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Kaliman, Zoran and Schnurrer-Luke-Vrbani\'{c}, Tea and Jurkovi\'{c}, Slaven}, year = {2019}, pages = {6}, DOI = {10.1016/j.ultras.2019.06.005}, chapter = {105943}, keywords = {ultrasound therapy, thermochromic material, effective radiating area, beam non - uniformity ratio}, journal = {Ultrasonics}, doi = {10.1016/j.ultras.2019.06.005}, volume = {99}, issn = {0041-624X}, title = {Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material}, keyword = {ultrasound therapy, thermochromic material, effective radiating area, beam non - uniformity ratio}, chapternumber = {105943} }
@article{article, author = {\v{Z}auhar, Gordana and Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Kaliman, Zoran and Schnurrer-Luke-Vrbani\'{c}, Tea and Jurkovi\'{c}, Slaven}, year = {2019}, pages = {6}, DOI = {10.1016/j.ultras.2019.06.005}, chapter = {105943}, keywords = {ultrasound therapy, thermochromic material, effective radiating area, beam non - uniformity ratio}, journal = {Ultrasonics}, doi = {10.1016/j.ultras.2019.06.005}, volume = {99}, issn = {0041-624X}, title = {Determination of Physiotherapy Ultrasound Beam Quality Parameters From Images Derived Using Thermochromic Material}, keyword = {ultrasound therapy, thermochromic material, effective radiating area, beam non - uniformity ratio}, chapternumber = {105943} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font