Pregled bibliografske jedinice broj: 1014001
Probability risk assessment of island operation event for large scale photovoltaic plant
Probability risk assessment of island operation event for large scale photovoltaic plant // Automatika : časopis za automatiku, mjerenje, elektroniku, računarstvo i komunikacije, 60 (2019), 2; 181-192 doi:10.1080/00051144.2019.1591071 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1014001 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Probability risk assessment of island operation event for large scale photovoltaic plant
Autori
Ivas, Mihovil ; Marušić, Ante ; Havelka, Juraj George ; Capuder, Tomislav
Izvornik
Automatika : časopis za automatiku, mjerenje, elektroniku, računarstvo i komunikacije (0005-1144) 60
(2019), 2;
181-192
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
photovoltaic plant ; island operation ; probability risk assessment ; medium voltage ; loss of mains protection
Sažetak
Original methodology for the calculation of island operation event occurrence possibility is proposed for the photovoltaic power plants connected to medium voltage grid. Within the methodology description, event fault tree with number of pairs of basic initial events is discussed, where probability for the basic events are defined and flow chart for the proposed calculation is given. The novelty in the approach for probability calculation includes also proposal for development of frequency distribution functions for concerned power generation and consumption variables which have to be modelled for the probability calculations, for which the triangular distributions curves have been chosen. Being boundary conditions for definition of non-detected island event, borders of non-detection zones are defined for the common island detection protection functions: over frequency and under frequency, over voltage and under voltage and rate of change of frequency functions. Comparison of the island event probability is presented on case study example, with conclusion that standard voltage and frequency protection alone are not satisfying, but ROCOF protection could be suitable, subject to particular local grid characteristic and calculative verification of probability.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus