Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1013855

Calibration of the photon spectrometer PHOS of the ALICE experiment


(ALICE Collaboration) Acharya, S.; ...; Antičić, Tome; ...; Erhardt, Filip; ...; Gotovac, Sven; ...; Jerčić, Marko; ... et al.
Calibration of the photon spectrometer PHOS of the ALICE experiment // Journal of Instrumentation, 14 (2019), 05; P05025, 26 doi:10.1088/1748-0221/14/05/p05025 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1013855 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Calibration of the photon spectrometer PHOS of the ALICE experiment

Autori
Acharya, S. ; ... ; Antičić, Tome ; ... ; Erhardt, Filip ; ... ; Gotovac, Sven ; ... ; Jerčić, Marko ; ... ; Lončar, Petra ; ... ; Mudnić, Eugen ; ... ; Planinić, Mirko ; ... ; Poljak, Nikola ; ... ; Simatović, Goran ; ... ; Utrobičić, Antonija ; ... ; Vicković, Linda ; ... ; Zurlo, N.

Kolaboracija
ALICE Collaboration

Izvornik
Journal of Instrumentation (1748-0221) 14 (2019), 05; P05025, 26

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
energy calibration ; calorimeter electromagnetic ; alignment geometrical ; photon spectrometer ; ALICE ; mass resolution ; performance

Sažetak
The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time- dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton- proton (pp) collisions at √s=13 TeV. After applying all corrections, the achieved mass resolutions for π0 and η mesons for pT > 1.7 GeV/c are σmπ0 = 4.56 ± 0.03 MeV/c2 and σmη = 15.3 ± 1.0 MeV/c2, respectively.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
HRZZ-IP-2018-01-4108 - Demistificiranje dvočestičnih korelacija u pp sudarima s nadograđenom komorom vremenske projekcije (TPCwithTPC) (Planinić, Mirko, HRZZ - 2018-01) ( CroRIS)

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Institut "Ruđer Bošković", Zagreb,
Prirodoslovno-matematički fakultet, Zagreb

Citiraj ovu publikaciju:

(ALICE Collaboration) Acharya, S.; ...; Antičić, Tome; ...; Erhardt, Filip; ...; Gotovac, Sven; ...; Jerčić, Marko; ... et al.
Calibration of the photon spectrometer PHOS of the ALICE experiment // Journal of Instrumentation, 14 (2019), 05; P05025, 26 doi:10.1088/1748-0221/14/05/p05025 (međunarodna recenzija, članak, znanstveni)
(ALICE Collaboration) (ALICE Collaboration) Acharya, S., ..., Antičić, T., ..., Erhardt, F., ..., Gotovac, S., ..., Jerčić, M. & ... et al. (2019) Calibration of the photon spectrometer PHOS of the ALICE experiment. Journal of Instrumentation, 14 (05), P05025, 26 doi:10.1088/1748-0221/14/05/p05025.
@article{article, author = {Acharya, S. and Anti\v{c}i\'{c}, Tome and Erhardt, Filip and Gotovac, Sven and Jer\v{c}i\'{c}, Marko and Lon\v{c}ar, Petra and Mudni\'{c}, Eugen and Planini\'{c}, Mirko and Poljak, Nikola and Simatovi\'{c}, Goran and Utrobi\v{c}i\'{c}, Antonija and Vickovi\'{c}, Linda and Zurlo, N.}, year = {2019}, pages = {26}, DOI = {10.1088/1748-0221/14/05/p05025}, chapter = {P05025}, keywords = {energy calibration, calorimeter electromagnetic, alignment geometrical, photon spectrometer, ALICE, mass resolution, performance}, journal = {Journal of Instrumentation}, doi = {10.1088/1748-0221/14/05/p05025}, volume = {14}, number = {05}, issn = {1748-0221}, title = {Calibration of the photon spectrometer PHOS of the ALICE experiment}, keyword = {energy calibration, calorimeter electromagnetic, alignment geometrical, photon spectrometer, ALICE, mass resolution, performance}, chapternumber = {P05025} }
@article{article, author = {Acharya, S. and Anti\v{c}i\'{c}, Tome and Erhardt, Filip and Gotovac, Sven and Jer\v{c}i\'{c}, Marko and Lon\v{c}ar, Petra and Mudni\'{c}, Eugen and Planini\'{c}, Mirko and Poljak, Nikola and Simatovi\'{c}, Goran and Utrobi\v{c}i\'{c}, Antonija and Vickovi\'{c}, Linda and Zurlo, N.}, year = {2019}, pages = {26}, DOI = {10.1088/1748-0221/14/05/p05025}, chapter = {P05025}, keywords = {energy calibration, calorimeter electromagnetic, alignment geometrical, photon spectrometer, ALICE, mass resolution, performance}, journal = {Journal of Instrumentation}, doi = {10.1088/1748-0221/14/05/p05025}, volume = {14}, number = {05}, issn = {1748-0221}, title = {Calibration of the photon spectrometer PHOS of the ALICE experiment}, keyword = {energy calibration, calorimeter electromagnetic, alignment geometrical, photon spectrometer, ALICE, mass resolution, performance}, chapternumber = {P05025} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font