SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE


Krhač, Maja; Grdiša, Katarina; Vučić Lovrenčić, Marijana
SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE // 5th EFLM Conference on Preanalytical Phase, Preanalytical challenges - time for solutions / Plebani, Mario (ur.).
Berlin: Walter de Gruyter, 2019. str. eA49-eA49 doi:10.1515/cclm-2019-0104 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 1009358 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE

Autori
Krhač, Maja ; Grdiša, Katarina ; Vučić Lovrenčić, Marijana

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
5th EFLM Conference on Preanalytical Phase, Preanalytical challenges - time for solutions / Plebani, Mario - Berlin : Walter de Gruyter, 2019, EA49-eA49

Skup
5th EFLM Conference on Preanalytical Phase

Mjesto i datum
Zagreb, Hrvatska, 22.03.2019. - 23.03.2019

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
insulin stability, EDTA-plasma, SST-serum gel separator tubes

Sažetak
BACKGROUND-AIM: Measurement of the levels of blood insulin, a hormone responsible for the blood glucose regulation, may be a useful tool for the assessment of insulin resistance in type 2 diabetes and metabolic syndrome management. However, sample type together with overall stability is of great importance because insulin is easily degraded by circulating peptidases. Previous reports indicate that concentration remains stable in EDTA plasma, but not serum samples for 24 hours. The aim of our study was to compare insulin levels in two sample types, recommended plasma from EDTA-containing tubes (BD™ Vacutainer™K3EDTA Tubes, USA) and a serum from tubes with a new generation of gel separator (BD Vacutainer™SST™, USA). Additionally, we assessed insulin stability in both sample types within 24 hour storage at room temperature and +4oC. METHODS: Venus blood was sampled from 18 volunteers parallel in SST-serum tubes and EDTA-containing tubes. After centrifugation, analysis was done immediately and after 24 hour storage in different temperature conditions (room temperature and +4oC). Plasma samples were transferred in secondary tubes while the serum separation was obtained by gel in SST-tubes. Insulin was measured on ADVIA Centaur-XP analytical system (Siemens Healthineers, USA). RESULTS: Passing Bablok regression analysis revealed proportional differences for insulin concentration in fresh samples from SST-serum compared to EDTA-plasma tubes (y =-3, 1115(95% CI = -18, 4947 to 3, 5230) + 1, 1531(95% CI = 1, 0228 to 1, 3646)x). Regarding sample stability, insulin levels in SST-serum samples were found to be significantly lower in both samples stored at room temperature and +4oC (P = 0, 0235), while EDTA-plasma samples obtained satisfactory stability (P = 0, 6599 ; Kruskall Wallis ANOVA). CONCLUSIONS: SST-serum tubes could not preserve insulin from degradation for 24 hour period regardless of the storage temperature.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinička bolnica "Merkur"

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com

Citiraj ovu publikaciju:

Krhač, Maja; Grdiša, Katarina; Vučić Lovrenčić, Marijana
SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE // 5th EFLM Conference on Preanalytical Phase, Preanalytical challenges - time for solutions / Plebani, Mario (ur.).
Berlin: Walter de Gruyter, 2019. str. eA49-eA49 doi:10.1515/cclm-2019-0104 (poster, međunarodna recenzija, sažetak, znanstveni)
Krhač, M., Grdiša, K. & Vučić Lovrenčić, M. (2019) SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE. U: Plebani, M. (ur.)5th EFLM Conference on Preanalytical Phase, Preanalytical challenges - time for solutions doi:10.1515/cclm-2019-0104.
@article{article, author = {Krha\v{c}, Maja and Grdi\v{s}a, Katarina and Vu\v{c}i\'{c} Lovren\v{c}i\'{c}, Marijana}, editor = {Plebani, M.}, year = {2019}, pages = {eA49-eA49}, DOI = {10.1515/cclm-2019-0104}, keywords = {insulin stability, EDTA-plasma, SST-serum gel separator tubes}, doi = {10.1515/cclm-2019-0104}, title = {SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE}, keyword = {insulin stability, EDTA-plasma, SST-serum gel separator tubes}, publisher = {Walter de Gruyter}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Krha\v{c}, Maja and Grdi\v{s}a, Katarina and Vu\v{c}i\'{c} Lovren\v{c}i\'{c}, Marijana}, editor = {Plebani, M.}, year = {2019}, pages = {eA49-eA49}, DOI = {10.1515/cclm-2019-0104}, keywords = {insulin stability, EDTA-plasma, SST-serum gel separator tubes}, doi = {10.1515/cclm-2019-0104}, title = {SHORT-TERM STABILITY OF INSULIN IN SAMPLES FROM DIFFERENT BLOOD COLLECTION TUBE}, keyword = {insulin stability, EDTA-plasma, SST-serum gel separator tubes}, publisher = {Walter de Gruyter}, publisherplace = {Zagreb, Hrvatska} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font