Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1008712

Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position


Šribar, Andrej; Merc, Vlasta; Peršec, Zoran; Peršec, Jasminka; Milas, Ivan; Husedžinović, Sanja
Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position // Journal of clinical monitoring and computing, 34 (2019), 311-318 doi:10.1007/s10877-019-00318-8 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1008712 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position

Autori
Šribar, Andrej ; Merc, Vlasta ; Peršec, Zoran ; Peršec, Jasminka ; Milas, Ivan ; Husedžinović, Sanja

Izvornik
Journal of clinical monitoring and computing (1387-1307) 34 (2019); 311-318

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Mechanical ventilation ; Electrical impedance tomography ; Lateral position ; Urology ; PEEP

Sažetak
To determine the effect of various PEEP levels on electrical impedance tomography (EIT) measured differences in regional ventilation, hemodynamics, lung mechanics and parameters of alveolar gas exchange. Thirty three patients scheduled for elective urologic surgery in general anesthesia in lateral decubitus position were randomized into three groups—PEEP 0, 5 and 10 mbar. EIT recording, arterial blood gas analysis and hemodynamic parameters were captured at three timepoints—before induction (T0), 5 min after lateral positioning (T1) and 90 min after positioning (T2). Dynamic compliance (Cdyn) was measured at T1 and T2. Offline EIT data analysis was performed to calculate EIT derived parameters of ventilation distribution. Patients ventilated with PEEP of 10 mbar had a significantly lower A-a (alveolo arterial) gradient over measurements and symmetrical distribution of ventilation measured by EIT. There was no significant difference in Cdyn, center of ventilation indices and inhomogeneity index between groups. There was no difference of mean arterial pressure, cardiac index and heart rate between groups. Patients with 5 mbar of PEEP had higher stroke volume index compared to 0 and 10 mbar at baseline and over measurements. Nondependent/dependent TV ratio as well as global inhomogeneity index were correlated with A-a gradient. Dynamic compliance showed no correlation to A-a gradient. In our study, a PEEP level of 10 mbar improved alveolar gas exchange without compromising hemodynamic stability in patients mechanically ventilated in the lateral decubitus position. EIT measured parameters may be used to determine optimal ventilation parameters in these patients with inhomogeneous lung mechanics. Further studies are needed in patients with various lung pathologies.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Stomatološki fakultet, Zagreb

Profili:

Avatar Url Ivan Milas (autor)

Avatar Url Zoran Peršec (autor)

Avatar Url Andrej Šribar (autor)

Avatar Url Jasminka Peršec (autor)

Poveznice na cjeloviti tekst rada:

doi doi.org

Citiraj ovu publikaciju:

Šribar, Andrej; Merc, Vlasta; Peršec, Zoran; Peršec, Jasminka; Milas, Ivan; Husedžinović, Sanja
Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position // Journal of clinical monitoring and computing, 34 (2019), 311-318 doi:10.1007/s10877-019-00318-8 (međunarodna recenzija, članak, znanstveni)
Šribar, A., Merc, V., Peršec, Z., Peršec, J., Milas, I. & Husedžinović, S. (2019) Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position. Journal of clinical monitoring and computing, 34, 311-318 doi:10.1007/s10877-019-00318-8.
@article{article, author = {\v{S}ribar, Andrej and Merc, Vlasta and Per\v{s}ec, Zoran and Per\v{s}ec, Jasminka and Milas, Ivan and Hused\v{z}inovi\'{c}, Sanja}, year = {2019}, pages = {311-318}, DOI = {10.1007/s10877-019-00318-8}, keywords = {Mechanical ventilation, Electrical impedance tomography, Lateral position, Urology, PEEP}, journal = {Journal of clinical monitoring and computing}, doi = {10.1007/s10877-019-00318-8}, volume = {34}, issn = {1387-1307}, title = {Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position}, keyword = {Mechanical ventilation, Electrical impedance tomography, Lateral position, Urology, PEEP} }
@article{article, author = {\v{S}ribar, Andrej and Merc, Vlasta and Per\v{s}ec, Zoran and Per\v{s}ec, Jasminka and Milas, Ivan and Hused\v{z}inovi\'{c}, Sanja}, year = {2019}, pages = {311-318}, DOI = {10.1007/s10877-019-00318-8}, keywords = {Mechanical ventilation, Electrical impedance tomography, Lateral position, Urology, PEEP}, journal = {Journal of clinical monitoring and computing}, doi = {10.1007/s10877-019-00318-8}, volume = {34}, issn = {1387-1307}, title = {Influence of different PEEP levels on electrical impedance tomography findings in patients under general anesthesia ventilated in the lateral decubitus position}, keyword = {Mechanical ventilation, Electrical impedance tomography, Lateral position, Urology, PEEP} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font