Exergy analysis of two water pumps from steam power plant at four different loads
Exergy analysis of two water pumps from steam power plant at four different loads // IV INTERNATIONAL SCIENTIFIC CONFERENCE INDUSTRY 4.0 - Summer Session - 2019 - PROCEEDINGS / Popov, Georgi ; Ovtcharova, Jivka (ur.).
Sofija: Scientific technical union of mechanical engineering Industry - 4.0, 2019. str. 65-68 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1007952 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Exergy analysis of two water pumps from steam power plant at four different loads
Autori
Mrzljak, Vedran ; Orović, Josip ; Poljak, Igor ; Čulin, Jelena
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
IV INTERNATIONAL SCIENTIFIC CONFERENCE INDUSTRY 4.0 - Summer Session - 2019 - PROCEEDINGS
/ Popov, Georgi ; Ovtcharova, Jivka - Sofija : Scientific technical union of mechanical engineering Industry - 4.0, 2019, 65-68
Skup
4th International Scientific Conference Industry 4.0 - Summer Session - 2019
Mjesto i datum
Burgas, Bugarska, 24.06.2019. - 27.06.2019
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Condensate extraction pump ; Boiler feed pump ; Exergy losses ; Exergy efficiency ; Ambient temperature variation
Sažetak
Paper presents exergy efficiency and loss analysis of condensate extraction pump (CEP) and main boiler feed pump (BFP) from a conventional steam power plant. Based on the required measured operating parameters at four different loads, it was observed that an increase in driving power for both pumps follows an increase in power plant cumulative developed power. Both analyzed pumps do not have the highest exergy losses at the highest observed load, as can be usually expected. Main boiler feed pump has the highest exergy efficiency, which is equal to 87.00%, at power plant nominal load, while the highest exergy efficiency of condensate extraction pump (95.77%) was observed at 60% of power plant nominal load. The influence of the ambient temperature on both pumps exergy efficiencies and losses is almost negligible.