Pregled bibliografske jedinice broj: 1007674
Exergy analysis of steam turbine governing valve from a super critical thermal power plant
Exergy analysis of steam turbine governing valve from a super critical thermal power plant // XXVII INTERNATIONAL SCIENTIFIC CONFERENCE trans & MOTAUTO ’19 - PROCEEDINGS / Kolev, Petar (ur.).
Sofija: Scientific technical union of mechanical engineering Industry - 4.0, 2019. str. 99-102 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 1007674 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Exergy analysis of steam turbine governing valve from a super critical thermal power plant
Autori
Mrzljak, Vedran ; Orović, Josip ; Poljak, Igor ; Lorencin, Ivan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
XXVII INTERNATIONAL SCIENTIFIC CONFERENCE trans & MOTAUTO ’19 - PROCEEDINGS
/ Kolev, Petar - Sofija : Scientific technical union of mechanical engineering Industry - 4.0, 2019, 99-102
Skup
27th International Scientific Technical Conference Trans & MOTAUTO
Mjesto i datum
Varna, Bugarska, 17.06.2019. - 20.06.2019
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Governing valve ; Exergy analysis ; Ambient temperature ; Super critical power plant
Sažetak
Exergy analysis of steam turbine governing valve from a super critical thermal power plant is presented in this paper. Governing valve was analyzed not only at the highest, but also on two partial steam system loads. The lowest valve exergy destruction is 3598 kW and is obtained at the highest steam system load, while at partial loads of 80% and 60% valve exergy destruction is 13550 kW and 21360 kW. Valve exergy efficiency increases with an increase in system load, from 95.58% at 60% of load to 97.87% at 80% of load. At the highest load, valve exergy efficiency is the highest and is 99.57%. Change in valve steam specific entropy increment (difference in steam specific entropy between valve outlet and inlet) can be used as a tool for quick assessment of valve losses change. The ambient temperature influence on governing valve exergy analysis is low, especially in the highest steam system load where the majority of valve operation can be expected.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo, Tehnologija prometa i transport
POVEZANOST RADA
Projekti:
HRZZ-IP-2018-01-3739 - Sustav potpore odlučivanju za zeleniju i sigurniju plovidbu brodova (DESSERT) (Prpić-Oršić, Jasna, HRZZ - 2018-01) ( CroRIS)
Ustanove:
Tehnički fakultet, Rijeka,
Sveučilište u Zadru