Pregled bibliografske jedinice broj: 1006071
Reporting categories in urine test strip analysis: Croatian survey and call for action
Reporting categories in urine test strip analysis: Croatian survey and call for action // Biochemia Medica, 29 (2019), 2; 020709, 13 doi:10.11613/bm.2018.020709 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 1006071 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Reporting categories in urine test strip analysis: Croatian survey and call for action
Autori
Dojder, Ana ; Vuljanić, Dora ; Špoljarić, Valentina ; Saračević, Andrea ; Dukić, Lora ; Leniček-Krleža, Jasna ; Vlašić-Tanasković, Jelena ; Maradin, Ivana ; Grzunov, Ana ; Šimundić, Ana-Maria
Izvornik
Biochemia Medica (1330-0962) 29
(2019), 2;
020709, 13
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
urine ; test strips ; reporting ; harmonization
Sažetak
Introduction In line with the national recommendations, Croatian medical laboratories report urine test strip qualitative analysis results using a categorized scale with defined number of categories. Since concentration ranges for measured analytes have not been provided by national professional authority, it is up to the laboratories to define their own categories. The aim of study was to assess the comparability of concentrations assigned to different categories used in reporting the results of dipstick urinalysis in Croatian laboratories. Material and methods A questionnaire was e-mailed to all Croatian medical laboratories (N = 195). They were asked to provide the number of categories and respective concentrations for each parameter. Data were described as numbers and percentages. Values above the upper reference range limit, which were assigned as normal and/or trace category, were considered as false negative. Results Response rate was 71% (139/195). Seventy percent (98/139) of laboratories report their results with either higher (77/98 ; 79%) or lower (2/98 ; 2%) number of categories, relative to the national recommendation, whereas 19/98 (19%) report their results as concentrations. Great heterogeneity of reporting categories was observed. Multiple categories were assigned to same concentrations and there was a large overlap of concentrations for most categories. Considerable proportion of laboratories reported false negative results for ketones (42%), leukocytes (30%) and glucose (21%). Conclusions The concentrations assigned to categories used to report the results of dipstick urinalysis are not comparable among Croatian medical laboratories. There is an urgent need for harmonization and standardization of reporting the results of urine dipstick analysis in Croatia.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Klinička bolnica "Sveti Duh",
Klinika za dječje bolesti
Profili:
Ana-Maria Šimundić
(autor)
Lora Dukić
(autor)
Andrea Saračević
(autor)
Jasna Leniček Krleža
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE