Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.


Lapić, Ivana; Piva, Elisa; Spolaore, Federica; Tosato, Francesca; Pelloso, Michela; Plebani; Mario
Automated measurement of the erythrocyte sedimentation rate: method validation and comparison. // Clinical chemistry and laboratory medicine, Aug 2019 (2019), 2019-0204, 10 doi:10.1515/cclm-2019-0204 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 1000663 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.

Autori
Lapić, Ivana ; Piva, Elisa ; Spolaore, Federica ; Tosato, Francesca ; Pelloso, Michela ; Plebani ; Mario

Izvornik
Clinical chemistry and laboratory medicine (1434-6621) Aug 2019 (2019); 2019-0204, 10

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
TEST1 ; Ves-Matic Cube 200 ; Westergren method ; erythrocyte sedimentation rate ; standardization ; validation

Sažetak
Background Development of automated analyzers for erythrocyte sedimentation rate (ESR) has imposed the need for extensive validation prior to their implementation in routine practice, to ensure comparability with the reference Westergren method. The aim of our study was to perform the analytical validation of two automated ESR analyzers, the Ves-Matic Cube 200 and the TEST1. Methods Validation was performed according to the recent International Council for Standardization in Hematology recommendations and included determination of intrarun and inter-run precision, assessment of sample carryover, hemolysis interference, sensitivity to fibrinogen, method comparison with the gold standard Westergren method and stability test. Results The highest intrarun imprecision was obtained for the low ESR range (33.5% for Ves-Matic Cube ; 37.3% for TEST1) while inter-run coefficients of variation on three levels were much better for the TEST1 (0%, 2% and 1.2%) compared to the Ves-Matic Cube 200 on two levels (24.9% and 5.8%). Both Ves-Matic Cube 200 and TEST1 showed no statistically significant difference when compared with Westergren. Bland-Altman analysis yielded overall insignificant mean biases for all comparisons, but a wider dispersion of results and 95% limits of agreement for comparisons including the Ves-Matic Cube 200. Carryover was considered insignificant, while hemolysis had a negative effect on all assessed ESR methods. The highest sensitivity to fibrinogen was observed for the Ves-Matic Cube 200, followed by Westergren and the least sensitive was the TEST1. Conclusions The obtained results proved the analytical validity of the TEST1 and the Ves-Matic Cube 200, and high comparability with the gold standard Westergren method, showing obvious improvements in standardization of ESR methods.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti, Interdisciplinarne biotehničke znanosti, Integrativna bioetika (prirodne, tehničke, biomedicina i zdravstvo, biotehničke, društvene, humanističke znanosti)



POVEZANOST RADA


Profili:

Avatar Url Ivana Lapić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Lapić, Ivana; Piva, Elisa; Spolaore, Federica; Tosato, Francesca; Pelloso, Michela; Plebani; Mario
Automated measurement of the erythrocyte sedimentation rate: method validation and comparison. // Clinical chemistry and laboratory medicine, Aug 2019 (2019), 2019-0204, 10 doi:10.1515/cclm-2019-0204 (međunarodna recenzija, članak, znanstveni)
Lapić, I., Piva, E., Spolaore, F., Tosato, F., Pelloso, M., Plebani & Mario (2019) Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.. Clinical chemistry and laboratory medicine, Aug 2019, 2019-0204, 10 doi:10.1515/cclm-2019-0204.
@article{article, author = {Lapi\'{c}, Ivana and Piva, Elisa and Spolaore, Federica and Tosato, Francesca and Pelloso, Michela}, year = {2019}, pages = {10}, DOI = {10.1515/cclm-2019-0204}, chapter = {2019-0204}, keywords = {TEST1, Ves-Matic Cube 200, Westergren method, erythrocyte sedimentation rate, standardization, validation}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2019-0204}, volume = {Aug 2019}, issn = {1434-6621}, title = {Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.}, keyword = {TEST1, Ves-Matic Cube 200, Westergren method, erythrocyte sedimentation rate, standardization, validation}, chapternumber = {2019-0204} }
@article{article, author = {Lapi\'{c}, Ivana and Piva, Elisa and Spolaore, Federica and Tosato, Francesca and Pelloso, Michela}, year = {2019}, pages = {10}, DOI = {10.1515/cclm-2019-0204}, chapter = {2019-0204}, keywords = {TEST1, Ves-Matic Cube 200, Westergren method, erythrocyte sedimentation rate, standardization, validation}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2019-0204}, volume = {Aug 2019}, issn = {1434-6621}, title = {Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.}, keyword = {TEST1, Ves-Matic Cube 200, Westergren method, erythrocyte sedimentation rate, standardization, validation}, chapternumber = {2019-0204} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font