Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 996271

Angle vs. LabSOCS for HPGe efficiency calibration


Stanić, Goran; Nikolov, Jovana; Tucaković, Ivana; Mrđa, Dušan; Todorović, Nataša; Grahek, Željko; Coha, Ivana; Vraničar, Andrej
Angle vs. LabSOCS for HPGe efficiency calibration // Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 920 (2019), 81-87 doi:10.1016/j.nima.2018.12.059 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 996271 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Angle vs. LabSOCS for HPGe efficiency calibration

Autori
Stanić, Goran ; Nikolov, Jovana ; Tucaković, Ivana ; Mrđa, Dušan ; Todorović, Nataša ; Grahek, Željko ; Coha, Ivana ; Vraničar, Andrej

Izvornik
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment (0168-9002) 920 (2019); 81-87

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Efficiency calibration ; Angle ; LabSOCS ; Gamma spectrometry

Sažetak
The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available. The aim of this work was to compare different methods and software used for efficiency calibration modeling and analyses. For that purpose, same samples of vegetation and soil of known activities were measured using HPGe detectors in two laboratories which are employing different software for mathematical efficiency calibrations and analyses, LabSOCS which is based on purely mathematical calculations and Angle which uses a semi-empirical approach. The codes were also tested on samples with unknown reference values (different geometries and matrices). The main advantages and disadvantages of both software were compared. Both Angle and LabSOCS gave comparable and consistent results for different detectors, matrices and geometries used. Deviations of the order of 10% or less obtained from the comparison of different sets of parameters are acceptable and imply that Angle and LabSOCS can be considered reliable for gamma ray detector efficiency calibrations. The main limitation of LabSOCS is in its inability to be used on newly installed detectors (factory characterization needed first), as for Angle the main drawback is in its demand for reference materials which can be costly as well as the need for plenty detector characteristics which are not always provided by the manufacturer.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Ivana Tucaković (autor)

Avatar Url Ivana Coha (autor)

Avatar Url Željko Grahek (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Stanić, Goran; Nikolov, Jovana; Tucaković, Ivana; Mrđa, Dušan; Todorović, Nataša; Grahek, Željko; Coha, Ivana; Vraničar, Andrej
Angle vs. LabSOCS for HPGe efficiency calibration // Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 920 (2019), 81-87 doi:10.1016/j.nima.2018.12.059 (međunarodna recenzija, članak, znanstveni)
Stanić, G., Nikolov, J., Tucaković, I., Mrđa, D., Todorović, N., Grahek, Ž., Coha, I. & Vraničar, A. (2019) Angle vs. LabSOCS for HPGe efficiency calibration. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 920, 81-87 doi:10.1016/j.nima.2018.12.059.
@article{article, author = {Stani\'{c}, Goran and Nikolov, Jovana and Tucakovi\'{c}, Ivana and Mr\dja, Du\v{s}an and Todorovi\'{c}, Nata\v{s}a and Grahek, \v{Z}eljko and Coha, Ivana and Vrani\v{c}ar, Andrej}, year = {2019}, pages = {81-87}, DOI = {10.1016/j.nima.2018.12.059}, keywords = {Efficiency calibration, Angle, LabSOCS, Gamma spectrometry}, journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, doi = {10.1016/j.nima.2018.12.059}, volume = {920}, issn = {0168-9002}, title = {Angle vs. LabSOCS for HPGe efficiency calibration}, keyword = {Efficiency calibration, Angle, LabSOCS, Gamma spectrometry} }
@article{article, author = {Stani\'{c}, Goran and Nikolov, Jovana and Tucakovi\'{c}, Ivana and Mr\dja, Du\v{s}an and Todorovi\'{c}, Nata\v{s}a and Grahek, \v{Z}eljko and Coha, Ivana and Vrani\v{c}ar, Andrej}, year = {2019}, pages = {81-87}, DOI = {10.1016/j.nima.2018.12.059}, keywords = {Efficiency calibration, Angle, LabSOCS, Gamma spectrometry}, journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment}, doi = {10.1016/j.nima.2018.12.059}, volume = {920}, issn = {0168-9002}, title = {Angle vs. LabSOCS for HPGe efficiency calibration}, keyword = {Efficiency calibration, Angle, LabSOCS, Gamma spectrometry} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font