Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 995544

The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites


Par, Matej; Repušić, Igor; Skenderović, Hrvoje; Milat, Ognjen; Spajić, Jelena; Tarle, Zrinka
The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites // Clinical oral investigations, 23 (2019), 10; 3777-3788 doi:10.1007/s00784-019-02807-1 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 995544 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites

Autori
Par, Matej ; Repušić, Igor ; Skenderović, Hrvoje ; Milat, Ognjen ; Spajić, Jelena ; Tarle, Zrinka

Izvornik
Clinical oral investigations (1432-6981) 23 (2019), 10; 3777-3788

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Resin composites ; Radiant energy ; Microhardness ; Temperature ;

Sažetak
Objectives To investigate radiant energy, microhardness, and temperature rise in eight resin composites cured with a blue or violet- blue curing unit, using a curing protocol which exceeded manufacturer recommendations. Materials and methods Cylindrical composite specimens (d = 8 mm, h = 2 or 4 mm, n = 5 per experimental group) were lightcured for 30 s. Light transmittance through specimens was recorded in real time to calculate radiant energy delivered to the specimen bottom. Vickers microhardness was used to evaluate the polymerization effectiveness at depth. Temperature rise at the bottom of the specimens was measured in real time using a T-type thermocouple. Results Radiant energy delivered from the blue and violet-blue curing unit amounted to 19.4 and 28.6 J/cm2, which was 19 and 13%lower than specified by the manufacturer. Radiant energies at bottom surfaces (0.2–7.5 J/cm2) were significantly affected by material, thickness, and curing unit. All of the composites reached 80% of maximum microhardness at clinically relevant layer thicknesses. The benefit of using the higher-irradiance violet-blue curing unit was identified only in composites containing alternative photoinitiators. Temperature rise during curing ranged from 4.4 to 9.3 °C and was significantly reduced by curing with the lower- intensity blue curing unit and by increasing layer thickness. Conclusion Curing for 30 s, which can be regarded as extended considering manufacturer specifications, produced radiant energies which are in line with the recommendations from the current scientific literature, leading to adequate curing efficiency and acceptable temperature rise. Clinical relevance Extended curing time should be used to minimize concerns regarding undercuring of composite restorations.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Dentalna medicina



POVEZANOST RADA


Ustanove:
Institut za fiziku, Zagreb,
Stomatološki fakultet, Zagreb

Profili:

Avatar Url Ognjen Milat (autor)

Avatar Url Zrinka Tarle (autor)

Avatar Url Matej Par (autor)

Avatar Url Hrvoje Skenderović (autor)

Poveznice na cjeloviti tekst rada:

doi doi.org

Citiraj ovu publikaciju:

Par, Matej; Repušić, Igor; Skenderović, Hrvoje; Milat, Ognjen; Spajić, Jelena; Tarle, Zrinka
The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites // Clinical oral investigations, 23 (2019), 10; 3777-3788 doi:10.1007/s00784-019-02807-1 (međunarodna recenzija, članak, znanstveni)
Par, M., Repušić, I., Skenderović, H., Milat, O., Spajić, J. & Tarle, Z. (2019) The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites. Clinical oral investigations, 23 (10), 3777-3788 doi:10.1007/s00784-019-02807-1.
@article{article, author = {Par, Matej and Repu\v{s}i\'{c}, Igor and Skenderovi\'{c}, Hrvoje and Milat, Ognjen and Spaji\'{c}, Jelena and Tarle, Zrinka}, year = {2019}, pages = {3777-3788}, DOI = {10.1007/s00784-019-02807-1}, keywords = {Resin composites, Radiant energy, Microhardness, Temperature, }, journal = {Clinical oral investigations}, doi = {10.1007/s00784-019-02807-1}, volume = {23}, number = {10}, issn = {1432-6981}, title = {The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites}, keyword = {Resin composites, Radiant energy, Microhardness, Temperature, } }
@article{article, author = {Par, Matej and Repu\v{s}i\'{c}, Igor and Skenderovi\'{c}, Hrvoje and Milat, Ognjen and Spaji\'{c}, Jelena and Tarle, Zrinka}, year = {2019}, pages = {3777-3788}, DOI = {10.1007/s00784-019-02807-1}, keywords = {Resin composites, Radiant energy, Microhardness, Temperature, }, journal = {Clinical oral investigations}, doi = {10.1007/s00784-019-02807-1}, volume = {23}, number = {10}, issn = {1432-6981}, title = {The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites}, keyword = {Resin composites, Radiant energy, Microhardness, Temperature, } }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font