Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 992757

Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction


Rincic Mlinaric, Marijana; Karlovic, Sven; Ciganj, Zlatko; Acev, Darko Pop; Pavlic, Andrej; Spalj, Stjepan
Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction // Odontology, 107 (2019), 2; 150-157 doi:10.1007/s10266-018-0387-9 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 992757 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction
(Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction)

Autori
Rincic Mlinaric, Marijana ; Karlovic, Sven ; Ciganj, Zlatko ; Acev, Darko Pop ; Pavlic, Andrej ; Spalj, Stjepan

Izvornik
Odontology (1618-1247) 107 (2019), 2; 150-157

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Antiseptics ; Corrosion ; Nickel ; Orthodontics ; Titanium

Sažetak
The effect of oral antiseptics on the corrosion of nickel-titanium (NiTi) alloys with various coating was investigated. Uncoated, titanium nitride- coated and rhodium-coated NiTi archwires (0.020 × 0.020″) were tested in interaction with artificial saliva pH 4.8 and oral antiseptics based on hyaluronic acid (Gengigel), chlorhexidine (Curasept) and essential oils in alcohol base (Listerine). The dynamics of nickel and titanium ions release were recorded during 28 days. Springback ratio and modulus of resilience were assessed by three-point bending test. The results showed that corrosion of NiTi is related to type of antiseptic mouth rinse and coating formulations. Exposure to an artificial saliva and antiseptics tend to reduce flexibility and resilience of NiTi archwires. The influence of the media is more significant than the influence of the type of the alloys coating. The largest release of nickel ions is in the first 3 days. Antiseptics do not cause further deterioration of the elastic properties in uncoated NiTi compared to saliva. As a result of exposure of nitrified NiTi wires in Listerine, there is bigger release of nickel ions, decrease in elastic properties and lower force delivery in unload. Listerine tends to reduce elastic properties of rhodium- coated wires also. In conclusion, except for Listerine, changes of mechanical characteristics induced by antiseptics are small and would not have a clinically important impact. Generally, Curasept would be the most suitable option.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina

Napomena
Funded by Croatian Scienece Foundation (IP-2014-09-7500)



POVEZANOST RADA


Projekti:
--IP-2014-09-7500 - Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata (IMUNODENT) (Špalj, Stjepan) ( CroRIS)

Ustanove:
Prehrambeno-biotehnološki fakultet, Zagreb,
Medicinski fakultet, Rijeka,
Stomatološki fakultet, Zagreb,
Fakultet za dentalnu medicinu i zdravstvo, Osijek

Poveznice na cjeloviti tekst rada:

doi link.springer.com

Citiraj ovu publikaciju:

Rincic Mlinaric, Marijana; Karlovic, Sven; Ciganj, Zlatko; Acev, Darko Pop; Pavlic, Andrej; Spalj, Stjepan
Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction // Odontology, 107 (2019), 2; 150-157 doi:10.1007/s10266-018-0387-9 (međunarodna recenzija, članak, znanstveni)
Rincic Mlinaric, M., Karlovic, S., Ciganj, Z., Acev, D., Pavlic, A. & Spalj, S. (2019) Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction. Odontology, 107 (2), 150-157 doi:10.1007/s10266-018-0387-9.
@article{article, author = {Rincic Mlinaric, Marijana and Karlovic, Sven and Ciganj, Zlatko and Acev, Darko Pop and Pavlic, Andrej and Spalj, Stjepan}, year = {2019}, pages = {150-157}, DOI = {10.1007/s10266-018-0387-9}, keywords = {Antiseptics, Corrosion, Nickel, Orthodontics, Titanium}, journal = {Odontology}, doi = {10.1007/s10266-018-0387-9}, volume = {107}, number = {2}, issn = {1618-1247}, title = {Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction}, keyword = {Antiseptics, Corrosion, Nickel, Orthodontics, Titanium} }
@article{article, author = {Rincic Mlinaric, Marijana and Karlovic, Sven and Ciganj, Zlatko and Acev, Darko Pop and Pavlic, Andrej and Spalj, Stjepan}, year = {2019}, pages = {150-157}, DOI = {10.1007/s10266-018-0387-9}, keywords = {Antiseptics, Corrosion, Nickel, Orthodontics, Titanium}, journal = {Odontology}, doi = {10.1007/s10266-018-0387-9}, volume = {107}, number = {2}, issn = {1618-1247}, title = {Oral antiseptics and nickel-titanium alloys: mechanical and chemical effects of interaction}, keyword = {Antiseptics, Corrosion, Nickel, Orthodontics, Titanium} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font