Pregled bibliografske jedinice broj: 985004
Dealing with interferences caused by presented M- protein
Dealing with interferences caused by presented M- protein // Clinical Chemistry and Laboratory Medicine / Plebani, Mario (ur.).
Berlin: Walter de Gruyter, 2019. str. eA8-eA8 doi:10.1515/cclm-2019-0104 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 985004 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Dealing with interferences caused by presented M- protein
Autori
Dojder, Ana ; Vuljanić, Dora ; Kuktić, Ivona ; Radišić Biljak, Vanja ; Šegulja, Dragana ; Nikolac Gabaj, Nora ; Šimundić, Ana-Maria
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Clinical Chemistry and Laboratory Medicine
/ Plebani, Mario - Berlin : Walter de Gruyter, 2019, EA8-eA8
Skup
5th EFLM Conference on Preanalytical Phase
Mjesto i datum
Zagreb, Hrvatska, 22.03.2019. - 23.03.2019
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
preanalytical phase, bilirubin, interference, multiple myeloma, M-protein
Sažetak
Background M-proteins are endogenous interferents. Although M-protein interference has long been recognized, detection and management of samples affected by M-protein interference remains a challenge for laboratories worldwide. Here we present a case of M-protein interference on direct bilirubin measurement and how to deal with it in order to report accurate and reliable results to the requesting physician. Material and methods A 76 year old female patient with a previously known diagnosis of multiple myeloma has had her regular check-up. Her serum proteins were 95 g/L at the time. Concentrations of direct and total bilirubin analyzed by AU860 (Beckman Coulter, USA) analyzer were -12.3 and 8.5 µmol/L, respectively. Since M-protein interference was suspected, sample was diluted with distilled water (1:10 ratio) to gain the lower concentration of M-proteins, treated with PEG to precipitate them, and treated with HBT to exclude the heterophilic interference. Once interference was confirmed, sample was sent to two other laboratories and analyzed on two different analyzers: Cobas 6000 (Roche, Switzerland) and Architect c8000 (Abbott, USA). Results The direct bilirubin concentration in diluted sample was 3.0 µmol/L. It was 4.0 µmol/L after PEG precipitation and -2.0 µmol/L after HBT treatment. Direct bilirubin concentration on different platforms were as follows: 1.6 µmol/L on Cobas 6000 and 2.8 µmol/L on Architect, revealing no interference. Conclusion In case when the interference of M- proteins is suspected, PEG precipitation and sample dilution with distilled water is sufficient to confirm interference. If accurate result is necessary, sample should be analyzed on a different instrument where interference is not present. HBT treatment is not effective in eliminating M-protein interference. Communication with a patient and a requesting physician is vital for proper management of this type of interference.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinička bolnica "Sveti Duh",
KBC "Sestre Milosrdnice"
Profili:
Dragana Šegulja
(autor)
Vanja Radišić Biljak
(autor)
Ana-Maria Šimundić
(autor)
Nora Nikolac
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- Scopus
- MEDLINE