New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination


Prkić, Ante; Vukušić, Tina; Mitar, Ivana; Giljanović, Josipa; Sokol, Vesna; Bošković, Perica; Jakić, Miće; Sedlar, Andrea
New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination // International Journal of Electrochemical Science, 14 (2019), 1; 861-874 doi:10.20964/2019.01.71 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 974037 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination

Autori
Prkić, Ante ; Vukušić, Tina ; Mitar, Ivana ; Giljanović, Josipa ; Sokol, Vesna ; Bošković, Perica ; Jakić, Miće ; Sedlar, Andrea

Izvornik
International Journal of Electrochemical Science (1452-3981) 14 (2019), 1; 861-874

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
chloride, potentiometric, determination, “homemade” ion-selective electrode, nanoparticles

Sažetak
This work describes preparation and application of “homemade” chloride ISE enriched with iron oxides or zinc oxide nanoparticles. The prepared chloride ISE membrane was made of AgCl:Ag2S:PTFE = 1:1:2 and AgCl:Ag2S:PTFE = 2:1:2 enriched with mentioned nanoparticles in ratio 0.5-1.2 wt.%. Prepared membranes were used for chloride determination in perchloric acid (pH = 0-2) and acetic buffer (pH = 4 – 4.75). Due to the low method price, simplicity and a reasonably fast way of usage, it was considered as a possibility for chloride determination in high acid media. Two of prepared membranes (M1 and M4) have shown best characteristics. M1 showed linear response range for chloride between 2.0×10−6 and 1×10−1 mol L−1, with a detection limit of 2.24×10−6 mol L−1 and potential change of 44.39 mV per decade. M4 showed linear response range for chloride between 4.2×10– 6 to 1×10–1 mol L−1, limit of detection of 1.39×10–6 mol L−1 with potential change of 24.79 mV per decade at pH = 0.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
Kemijsko-tehnološki fakultet, Split,
Prirodoslovno-matematički fakultet, Split

Profili:

Avatar Url Perica Bošković (autor)

Avatar Url Andrea Paut (autor)

Avatar Url Ante Prkić (autor)

Avatar Url Vesna Sokol (autor)

Avatar Url Josipa Giljanović (autor)

Avatar Url Miće Jakić (autor)

Avatar Url Ivana Mitar (autor)

Poveznice na cjeloviti tekst rada:

doi www.electrochemsci.org

Citiraj ovu publikaciju:

Prkić, Ante; Vukušić, Tina; Mitar, Ivana; Giljanović, Josipa; Sokol, Vesna; Bošković, Perica; Jakić, Miće; Sedlar, Andrea
New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination // International Journal of Electrochemical Science, 14 (2019), 1; 861-874 doi:10.20964/2019.01.71 (međunarodna recenzija, članak, znanstveni)
Prkić, A., Vukušić, T., Mitar, I., Giljanović, J., Sokol, V., Bošković, P., Jakić, M. & Sedlar, A. (2019) New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination. International Journal of Electrochemical Science, 14 (1), 861-874 doi:10.20964/2019.01.71.
@article{article, author = {Prki\'{c}, Ante and Vuku\v{s}i\'{c}, Tina and Mitar, Ivana and Giljanovi\'{c}, Josipa and Sokol, Vesna and Bo\v{s}kovi\'{c}, Perica and Jaki\'{c}, Mi\'{c}e and Sedlar, Andrea}, year = {2019}, pages = {861-874}, DOI = {10.20964/2019.01.71}, keywords = {chloride, potentiometric, determination, “homemade” ion-selective electrode, nanoparticles}, journal = {International Journal of Electrochemical Science}, doi = {10.20964/2019.01.71}, volume = {14}, number = {1}, issn = {1452-3981}, title = {New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination}, keyword = {chloride, potentiometric, determination, “homemade” ion-selective electrode, nanoparticles} }
@article{article, author = {Prki\'{c}, Ante and Vuku\v{s}i\'{c}, Tina and Mitar, Ivana and Giljanovi\'{c}, Josipa and Sokol, Vesna and Bo\v{s}kovi\'{c}, Perica and Jaki\'{c}, Mi\'{c}e and Sedlar, Andrea}, year = {2019}, pages = {861-874}, DOI = {10.20964/2019.01.71}, keywords = {chloride, potentiometric, determination, “homemade” ion-selective electrode, nanoparticles}, journal = {International Journal of Electrochemical Science}, doi = {10.20964/2019.01.71}, volume = {14}, number = {1}, issn = {1452-3981}, title = {New sensor based on AgCl containing Iron Oxide or Zinc Oxide Nanoparticles for Chloride Determination}, keyword = {chloride, potentiometric, determination, “homemade” ion-selective electrode, nanoparticles} }