Real Time Operation of Synchrophasor Data Functions in Transmission System Control Room
Real Time Operation of Synchrophasor Data Functions in Transmission System Control Room // 11th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion
Cavtat, Hrvatska, 2018. str. - (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 972284 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Real Time Operation of Synchrophasor Data Functions in Transmission System Control Room
Autori
Ivanković, Igor ; Rubeša, Renata ; Kuzle, Igor ; Rekić, Marko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
11th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion
/ - , 2018
Skup
11th Mediterranean Conference on Power Generation, Transmission, Distribution and Energy Conversion (MEDPOWER)
Mjesto i datum
Cavtat, Hrvatska, 12.11.2018. - 15.11.2018
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
synchrophasor data in control room ; monitoring of oscillations in transmission network ; monitoring of negative and zero component in transmsission network
Sažetak
Rare events and disturbances in transmission network can occur in some time frames or with some electrical values which are not fully covered with relay protection and SCADA systems. This gap can be fixed with Wide area monitoring system in control room. WAM system collects synchrophasor data from all 400 and 220 kV transmission lines. Inside WAM system special functions, based on synchrophasor data, were developed for these purposes. That way total monitoring for power oscillations in transmission network is established. These functions are in testing phase and will be connected to SCADA system in control room. New generations of Phasor measurement units send to control room values for all three phase values and positive, negative and zero components. Function for early warning also was developed based on negative and zero components. Special attention was put on communication channels and delay aspects. Special algorithms were implemented to override those aspects in communication channels. Few examples for those new functions will be elaborated and presented.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb