Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 964825

Genotoxic potential of commercial orthodontic adhesives in relation to curing time


Katić, Višnja
Genotoxic potential of commercial orthodontic adhesives in relation to curing time // Contributi Scientifici
Firenca, Italija, 2018. (poster, međunarodna recenzija, pp prezentacija, znanstveni)


CROSBI ID: 964825 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Genotoxic potential of commercial orthodontic adhesives in relation to curing time

Autori
Katić, Višnja

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, pp prezentacija, znanstveni

Izvornik
Contributi Scientifici / - , 2018

Skup
49th International SIDO Congress

Mjesto i datum
Firenca, Italija, 11.10.2018. - 13.10.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
genotoxicity ; orthodontic adhesives ; curing time

Sažetak
AIM: We aimed to assess the genotoxic potential of orthodontic adhesives on human lymphocytes. MATERIAL AND METHODS: Five adhesives were tested: Transbond XT ( 3M Unitek, USA) Transbond Plus (3M Unitek, USA), Light Bond (Reliance Orthodontic Products Inc., USA), Light Bond with Fluoride (Reliance Orthodontic Products Inc., USA) and Geristore (DenMat, USA). In a simulation of the clinical procedure, each adhesive was placed between two cellulose strips, covered with a metallic premolar bracket and illuminated for 10 or 20 seconds. Lymphocytes were obtained from a young, healthy, non-smoking donor. For the micronucleus assay, lymphocyte cultures were treated with samples for 24 h. Cell culture medium was used as negative and ethyl methanesulfonate in concentration 10 µg/mL of culture as positive control. Micronuclei were counted in 2000 binuclear cells per tested material. The experiment was performed in duplicate. Chi-square was used in statistical analysis. RESULTS: Differences in micronuclei formation between samples of the same adhesive with regards to curing time were not significant. Transbond Plus showed the highest frequency of micronuclei in both curing times, yet the difference was not significant. A significant increase in the formation of nuclear buds was also observed for Transbond Plus after 10 s of curing, however, it lacked biological relevance. CONCLUSION: Transbond Plus may induce increased DNA reparation, however, none of the tested adhesives showed genotoxic potential.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina

Napomena
Ovaj rad je sufinanciralo Sveučilište u Rijeci projektom 18.07.2.2.03.



POVEZANOST RADA


Projekti:
18.07.2.2.03

Ustanove:
Medicinski fakultet, Rijeka

Profili:

Avatar Url Višnja Katić (autor)

Poveznice na cjeloviti tekst rada:

congressosido2018.sido.it

Citiraj ovu publikaciju:

Katić, Višnja
Genotoxic potential of commercial orthodontic adhesives in relation to curing time // Contributi Scientifici
Firenca, Italija, 2018. (poster, međunarodna recenzija, pp prezentacija, znanstveni)
Katić, V. (2018) Genotoxic potential of commercial orthodontic adhesives in relation to curing time. U: Contributi Scientifici.
@article{article, author = {Kati\'{c}, Vi\v{s}nja}, year = {2018}, keywords = {genotoxicity, orthodontic adhesives, curing time}, title = {Genotoxic potential of commercial orthodontic adhesives in relation to curing time}, keyword = {genotoxicity, orthodontic adhesives, curing time}, publisherplace = {Firenca, Italija} }
@article{article, author = {Kati\'{c}, Vi\v{s}nja}, year = {2018}, keywords = {genotoxicity, orthodontic adhesives, curing time}, title = {Genotoxic potential of commercial orthodontic adhesives in relation to curing time}, keyword = {genotoxicity, orthodontic adhesives, curing time}, publisherplace = {Firenca, Italija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font