Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 954855

Three-dimensional Measurement of Temporal Articular- eminence Inclination


Kranjčić, Josip; Peršić Kiršić, Sanja; Kovačić, Ines; Čelebić, Asja; Vojvodić, Denis
Three-dimensional Measurement of Temporal Articular- eminence Inclination // EPA-SEPES Digital natives in prosthodontics / European Prosthodontic Association, EPA (ur.).
Madrid: European Pressphoto Agency (EPA), 2018. str. 160-160 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 954855 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Three-dimensional Measurement of Temporal Articular- eminence Inclination

Autori
Kranjčić, Josip ; Peršić Kiršić, Sanja ; Kovačić, Ines ; Čelebić, Asja ; Vojvodić, Denis

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
EPA-SEPES Digital natives in prosthodontics / European Prosthodontic Association, EPA - Madrid : European Pressphoto Agency (EPA), 2018, 160-160

Skup
42nd Annual Conference of the European Prosthodontic Association (EPA) and EPA-SEPES joint meeting

Mjesto i datum
Madrid, Španjolska, 13.09.2018. - 15.09.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
temporomandibular joint ; skull ; population

Sažetak
Objective: Inclination of articular-eminence posterior wall (AEI) is an important element in biomechanics of temporomandibular joint (TMJ). Therefore, the aim of this study was to measure AEI values between Croatian and American contemporary populations as well as to determine differences between two different methods used for AEI measurement. Methods: The study was carried out on 90 human (aged 18 to 55 years) dry skulls from 20th century: Croatian population (CP ; 30 skulls), American Caucasians (AC ; 30 skulls), and African Americans (AA ; 30 skulls). Silicone impressions of articular-eminence and fossa glenoidalis were made, and digitalized by optical scanner. Using appropriate software AEI measurement was performed on 5 simulated sections (from lateral to medial side) through the virtual impressions. AEI was measured in relation to the Frankfurt horizontal plane by two methods: „fossa roof–eminence top“ method (M1) and “best fit line“ method (M2). The results obtained were statistically analyzed at significance level of p<0.05. Results: Mean AEI M1 for CP was 34.6°, for AA 36.4°, and for AC 37.4°, while mean AEI M2 for CP was 53.9°, for AA 51.3°, and for AC 55.6°. AEI values between CP, AC, and AA were not statistically significant (p>0.05). Differences between two methods of AEI measurements (M1 and M2) were statistically significant with significantly higher AEI values measured when using method M2 (p<0.05). Conclusion: AEI values vary a lot with wide range of measured values. Differences in AEI values between three different populations existed, but were not statistically significant. Although both angles used for measurement represent the AEI, measured values obtained by M2 method were higher than values measured by M1 method. Therefore, it is of great importance to state which method was used when expressing AEI data.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Projekti:
MZOS-065-0650445-0413 - Istraživanje materijala i kliničkih postupaka u stomatološkoj protetici (Vojvodić, Denis, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb

Poveznice na cjeloviti tekst rada:

www.epa2018.sepes.org www.epa2018.sepes.org

Citiraj ovu publikaciju:

Kranjčić, Josip; Peršić Kiršić, Sanja; Kovačić, Ines; Čelebić, Asja; Vojvodić, Denis
Three-dimensional Measurement of Temporal Articular- eminence Inclination // EPA-SEPES Digital natives in prosthodontics / European Prosthodontic Association, EPA (ur.).
Madrid: European Pressphoto Agency (EPA), 2018. str. 160-160 (poster, međunarodna recenzija, sažetak, znanstveni)
Kranjčić, J., Peršić Kiršić, S., Kovačić, I., Čelebić, A. & Vojvodić, D. (2018) Three-dimensional Measurement of Temporal Articular- eminence Inclination. U: European Prosthodontic Association, E. (ur.)EPA-SEPES Digital natives in prosthodontics.
@article{article, author = {Kranj\v{c}i\'{c}, Josip and Per\v{s}i\'{c} Kir\v{s}i\'{c}, Sanja and Kova\v{c}i\'{c}, Ines and \v{C}elebi\'{c}, Asja and Vojvodi\'{c}, Denis}, editor = {European Prosthodontic Association, E.}, year = {2018}, pages = {160-160}, keywords = {temporomandibular joint, skull, population}, title = {Three-dimensional Measurement of Temporal Articular- eminence Inclination}, keyword = {temporomandibular joint, skull, population}, publisher = {European Pressphoto Agency (EPA)}, publisherplace = {Madrid, \v{S}panjolska} }
@article{article, author = {Kranj\v{c}i\'{c}, Josip and Per\v{s}i\'{c} Kir\v{s}i\'{c}, Sanja and Kova\v{c}i\'{c}, Ines and \v{C}elebi\'{c}, Asja and Vojvodi\'{c}, Denis}, editor = {European Prosthodontic Association, E.}, year = {2018}, pages = {160-160}, keywords = {temporomandibular joint, skull, population}, title = {Three-dimensional Measurement of Temporal Articular- eminence Inclination}, keyword = {temporomandibular joint, skull, population}, publisher = {European Pressphoto Agency (EPA)}, publisherplace = {Madrid, \v{S}panjolska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font