Pregled bibliografske jedinice broj: 950661
Ascorbic acid – black hole of urine chemistry screening
Ascorbic acid – black hole of urine chemistry screening // Journal of clinical laboratory analysis, 32 (2018), 5; e22390, 8 doi:10.1002/jcla.22390 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 950661 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Ascorbic acid – black hole of urine chemistry screening
Autori
Unic, Adriana ; Nikolac Gabaj, Nora ; Miler, Marijana ; Culej, Jelena ; Lisac, Adriana ; Horvat, Anita ; Vrkic, Nada
Izvornik
Journal of clinical laboratory analysis (0887-8013) 32
(2018), 5;
E22390, 8
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Urinalysis ; Diagnostic accuracy ; Interference ; Ascorbic acid
Sažetak
Study was performed in order: (i) to assess the comparability of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein ; (ii) to assess accuracy of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein ; and (iii) to evaluate interference of ascorbic acid on the glucose, bilirubin, hemoglobin, and nitrite determination using 2 different dipsticks: iChem Velocity, Iris Diagnostics and Combur-10M, Roche Diagnostics. Random urine specimens were included in the study. Comparability, accuracy, and ascorbic acid interference testing were performed. Obtained results have shown almost perfect agreement for all parameters between 2 dipsticks in samples with negative ascorbic acid. Agreement in samples with positive ascorbic acid was not acceptable for bilirubin, protein, nitrite, and hemoglobin. Accuracy was not acceptable for hemoglobin and leukocyte esterase on both dipsticks. Ascorbic acid interference examination has shown that intensity of interference differs between dipsticks. Ascorbic acid interferes with glucose, hemoglobin, nitrite, and bilirubin at different concentrations causing false-negative results. Obtained results indicate that it is necessary to determine diagnostic accuracy of used dipstick in order to define purpose of urinalysis. It is very important to choose dipstick with ascorbic acid indicator and to examine ascorbic acid impact on dipstick analytes independently of manufacturer claims.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Farmacija
Napomena
Rad/časoois indeksiran je i u: Natural Science Collection ; Nutrition Abstracts & Reviews Series A ; ProQuest Central ; Public Health Database ; PubMed Dietary Supplement Subset ; SciTech Premium Collection.
POVEZANOST RADA
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
KBC "Sestre Milosrdnice"
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- EMBASE (Excerpta Medica)
- Embase BIOBASE: Current Awareness in Biological Sciences
- Biological Science Database
- CABI
- Chemical Abstracts Service (CAS)
- Chemical Abstracts Service/SciFinder
- Dairy Science Abstracts
- EMCare
- Global Health
- Health & Medical Collection
- Health Research Premium Collection
- HEED
- Helminthological Abstracts
- Hospital Premium Collection (ProQuest)
- JCR/Science Edition