Pregled bibliografske jedinice broj: 947369
Functional Outcome Assessment of Lower Limb Amputees and Prosthetic Users with a 2-Minute Walk Test
Functional Outcome Assessment of Lower Limb Amputees and Prosthetic Users with a 2-Minute Walk Test // Collegium antropologicum, 35 (2011), 4; 1215-1218 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 947369 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Functional Outcome Assessment of Lower Limb Amputees and Prosthetic Users with a 2-Minute Walk Test
Autori
Frlan-Vrgoč, Ljubinka ; Schnurrer-Luke-Vrbanić, Tea ; Kraguljac, Darko ; Kovačević, Miljenko
Izvornik
Collegium antropologicum (0350-6134) 35
(2011), 4;
1215-1218
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
amputation, prosthesis, assessment, walk
Sažetak
The aim of this study was to assess the functional outcome of a population of lower limb amputees supplied with prosthesis. The research was conducted from June to September of 2010 at the Center for Physical and Rehabilitation Medicine, of the Clinical Hospital Center Rijeka, Croatia. The study included 50 adult subjects of both genders with a unilateral transtibial or transfemoral lower limb amputations. The 2-minute walk test (2MWT) was used to assess the functional outcome of these individuals. Data were statistically analyzed. Subjects were divided into groups according to age. The best results were obtained by subjects between the age of 45 and 59 years. The difference between groups was statistically significant (P<0.001). Taking into account the cause of amputation, there was a statistically significant difference in the results of the 2 MWT between subjects in whom the cause of amputation was circulatory and those where the cause of the amputation was not due to circulatory problems. The best results were obtained in subjects in whom the cause of amputation was not circulatory (P=0.009). Considering the level of amputation there was a statistically significant difference in the results of the 2MWT between subjects with transtibial and those with transfemoral amputations. Better results were obtained in transtibial amputees (P=0.039). Considering the first prosthetic supply, better results were obtained in subjects using prosthetic devices over 9 years (P=0.031). Our research confirmed that age, gender, level and cause of amputation, including the time from the first prosthetic supply have an effect on the 2MWT results.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinički bolnički centar Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Social Science Citation Index (SSCI)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE