Possibilities of Reliable Ultrasonic Detection of Subwavelength Pipework Cracks
Possibilities of Reliable Ultrasonic Detection of Subwavelength Pipework Cracks // Proceedings of the 12th International Conference of the Croatian Nuclear Society / Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2018. str. 118-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 946070 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Possibilities of Reliable Ultrasonic Detection of Subwavelength Pipework Cracks
Autori
Hrabar, Ivan ; Petošić, Antonio ; Franček, Petar ; Budimir, Marko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 12th International Conference of the Croatian Nuclear Society
/ Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica - Zagreb : Hrvatsko nuklearno društvo, 2018, 118-1
ISBN
978-953-48100-1-9
Skup
12th International Conference of the Croatian Nuclear Society
Mjesto i datum
Zadar, Hrvatska, 03.07.2018. - 06.07.2018
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
ultrasonic testing, NDT, subwavelength, transducer self-impedance
Sažetak
An occurrence of cracks in pipework could lead to potentially very dangerous malfunction in some critical engineering systems such as power plants. There is a clear trend of replacing traditional manual testing with non-invasive in- situ methods that should detect crack formation in its early stage. Such as approach would enable replacing of unhealthy pipe components during the regular periodic outages. Ultrasonic testing is known to be a rather mature and reliable technology. However, it suffers from serious problems in detection of the cracks of subwavelength size. This paper attempts to soften aforementioned problems by investigating the influence of a duration of the unipolar excitation signal on the achieved resolution. In addition, the transducer input electrical impedance of NDT transmitter was measured by using different excitation pulses and their levels and the results are compared with those obtained using traditional frequency sweeping method at low excitation levels. Finally, use of some advanced signal processing algorithms that might lead to the automatic detection of subwavelength voids, in scenarios with low signal-to-noise ratio, is discussed.