Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry


Smilović Radojčić, Đeni; Rajlić, David; Casar, Božidar; Švabić Kolacio, Manda; Obajdin, Nevena; Faj, Dario; Jurković, Slaven
Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry // Radiology and oncology, 52 (2018), 3; 346-352 doi:10.2478/raon-2018-0019 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 935953 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry

Autori
Smilović Radojčić, Đeni ; Rajlić, David ; Casar, Božidar ; Švabić Kolacio, Manda ; Obajdin, Nevena ; Faj, Dario ; Jurković, Slaven

Izvornik
Radiology and oncology (1318-2099) 52 (2018), 3; 346-352

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
IMRT ; 2D dose verification ; gamma method ; anthropomorphic phantom

Sažetak
Background. The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates was examined for beams of different complexity passing through inhomogeneous phantoms. Materials and methods. The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi- anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. Results. Passing rates of the complex dose distributions degrade depending on the thickness of non water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. Conclusions. Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Medicinski fakultet, Osijek,
Klinički bolnički centar Rijeka,
Fakultet za dentalnu medicinu i zdravstvo, Osijek

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com

Citiraj ovu publikaciju:

Smilović Radojčić, Đeni; Rajlić, David; Casar, Božidar; Švabić Kolacio, Manda; Obajdin, Nevena; Faj, Dario; Jurković, Slaven
Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry // Radiology and oncology, 52 (2018), 3; 346-352 doi:10.2478/raon-2018-0019 (međunarodna recenzija, članak, znanstveni)
Smilović Radojčić, Đ., Rajlić, D., Casar, B., Švabić Kolacio, M., Obajdin, N., Faj, D. & Jurković, S. (2018) Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry. Radiology and oncology, 52 (3), 346-352 doi:10.2478/raon-2018-0019.
@article{article, author = {Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Rajli\'{c}, David and Casar, Bo\v{z}idar and \v{S}vabi\'{c} Kolacio, Manda and Obajdin, Nevena and Faj, Dario and Jurkovi\'{c}, Slaven}, year = {2018}, pages = {346-352}, DOI = {10.2478/raon-2018-0019}, keywords = {IMRT, 2D dose verification, gamma method, anthropomorphic phantom}, journal = {Radiology and oncology}, doi = {10.2478/raon-2018-0019}, volume = {52}, number = {3}, issn = {1318-2099}, title = {Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry}, keyword = {IMRT, 2D dose verification, gamma method, anthropomorphic phantom} }
@article{article, author = {Smilovi\'{c} Radoj\v{c}i\'{c}, \DJeni and Rajli\'{c}, David and Casar, Bo\v{z}idar and \v{S}vabi\'{c} Kolacio, Manda and Obajdin, Nevena and Faj, Dario and Jurkovi\'{c}, Slaven}, year = {2018}, pages = {346-352}, DOI = {10.2478/raon-2018-0019}, keywords = {IMRT, 2D dose verification, gamma method, anthropomorphic phantom}, journal = {Radiology and oncology}, doi = {10.2478/raon-2018-0019}, volume = {52}, number = {3}, issn = {1318-2099}, title = {Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry}, keyword = {IMRT, 2D dose verification, gamma method, anthropomorphic phantom} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati: