Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement


Sorić, Zorislav; Tulin, Leonard
Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement // The Masonry Society Journal, 6 (1987), 1; T13-T27 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 93560 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement

Autori
Sorić, Zorislav ; Tulin, Leonard

Izvornik
The Masonry Society Journal (0741-1294) 6 (1987), 1; T13-T27

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
reinforced masonry; bond stress; slip; spliced reinforcement; monotonic and cyclic loading

Sažetak
Pull-Pull specimens consisting of grouted nominal six inch concrete or clay masonry block, reinforced with spliced #4 or #7 reinforcing bar, were subjected to monotonic or cycling loadings, while end-point displacements, relative displacements between the steel and the original plane of reference (slip), and strains in the steel were observed. The bond stress distribution between the steel and surrounding grout was calculated from the rate of change of the stress in the steel. Primary crack formation in the specimen increased the end point displacement, slip, and stress in the steel, while the overall stiffness of the specimen decreased. Cyclic loading produced progressive degradation of the specimen stiffness. Ductility of specimens was limited by the formation of longitudinal crack. Specimens reinforced with #4 bars were able to develop acceptable ductility, while those with #7 bars were unable to develop yield in the steel. It would appear that a limitation of maximum bar size as a function of thickness of wall could improve ductility by reducing the formation of longitudinal cracks.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Zorislav Sorić (autor)


Citiraj ovu publikaciju:

Sorić, Zorislav; Tulin, Leonard
Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement // The Masonry Society Journal, 6 (1987), 1; T13-T27 (međunarodna recenzija, članak, znanstveni)
Sorić, Z. & Tulin, L. (1987) Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement. The Masonry Society Journal, 6 (1), T13-T27.
@article{article, author = {Sori\'{c}, Zorislav and Tulin, Leonard}, year = {1987}, pages = {T13-T27}, keywords = {reinforced masonry, bond stress, slip, spliced reinforcement, monotonic and cyclic loading}, journal = {The Masonry Society Journal}, volume = {6}, number = {1}, issn = {0741-1294}, title = {Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement}, keyword = {reinforced masonry, bond stress, slip, spliced reinforcement, monotonic and cyclic loading} }
@article{article, author = {Sori\'{c}, Zorislav and Tulin, Leonard}, year = {1987}, pages = {T13-T27}, keywords = {reinforced masonry, bond stress, slip, spliced reinforcement, monotonic and cyclic loading}, journal = {The Masonry Society Journal}, volume = {6}, number = {1}, issn = {0741-1294}, title = {Bond Stress and Slip in Masonry Reinforced with Spliced Reinforcement}, keyword = {reinforced masonry, bond stress, slip, spliced reinforcement, monotonic and cyclic loading} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • SCI-EXP, SSCI i/ili A&HCI


Uključenost u ostale bibliografske baze podataka::


  • Civil Engineering





Contrast
Increase Font
Decrease Font
Dyslexic Font