Pregled bibliografske jedinice broj: 931835
Evaluation of breath alcohol analysers by comparison of breath and blood alcohol concentrations
Evaluation of breath alcohol analysers by comparison of breath and blood alcohol concentrations // Arhiv za higijenu rada i toksikologiju, 69 (2018), 1; 69-75 doi:10.2478/aiht-2018-69-3064 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 931835 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Evaluation of breath alcohol analysers by comparison of breath and blood alcohol concentrations
Autori
Jurič, Andreja ; Fijačko, Andrija ; Bakulić, Lana ; Orešić, Tanja ; Gmajnički, Ines
Izvornik
Arhiv za higijenu rada i toksikologiju (0004-1254) 69
(2018), 1;
69-75
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
breathalyser ; back calculation ; ethanol ; elimination factor ; gas chromatography, reliability
Sažetak
The main goal of this study was to determine the reliability of hand-held breath alcohol analysers currently approved for roadside screening of traffic offenders. The first part of the study included a retrospective data analysis of 714 offence records collected in 2011. Blood alcohol concentrations (BAC) obtained from the offenders 0-303 min after the police had screened them for breath alcohol concentration (BrAC) were back-calculated (cBAC) to assess the accuracy of breathalyser screening. All participants were in the alcohol elimination phase, and our analyses did not reveal any significant differences between cBAC and BrAC. To verify our findings, we performed a controlled drinking study that involved 63 healthy volunteers who consumed alcoholic beverages to simulate real drinking conditions. Immediately after alcohol consumption, BrAC was determined with a Dräger breath alcohol analyser model 6810, and 29 participants gave blood and urine sample for concomitant BAC analysis one hour later. BAC and urine alcohol concentrations were determined with headspace gas chromatography. Again, we found no significant differences between BrAC and BAC. These results confirmed the high reliability of breath alcohol analysers for measuring BrAC as long as police officers perform the measurements according to the manufacturer’s instructions.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Javno zdravstvo i zdravstvena zaštita
POVEZANOST RADA
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb,
Centar za forenzična ispitivanja, istraživanja i vještačenja "Ivan Vučetić"
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE